Kedida CT-6321 User Manual

Pen meter ph & conductivity

Advertisement

Quick Links

Pen Meter pH & Conductivity Users Manual
 Caution
Please read the manual carefully before using the meter.
The glass electrode at the bottom of the pen is fragile, please use it carefully after taking off the protection cap. Any
damage may cause the invalid of the electrode.
The duration period of the glass electrode is one year from the date of purchase whether you use it or not, please
change the electrode in time.
The electrode can not be used under the dry condition, always soak the electrode into the distilled water or purified
water for 5 – 30 minutes to activate before use.

FEATURES

* Water proof and protection
* Pen type digital pH& Conductivity meter, all in one,
Electrode is included, easy for general purpose
application
*℃/ ℉ Interchangeable
* Easy to change the pH electrode
* Three point calibration for pH 4.0, pH 6.8 and pH 9.1
(CT-6321)
* Three point calibration for pH 4.0, pH
7.0 and pH 10.0 (CT-6322)
1
S
H
E
N
Z
H
E
N
K
E
D
I
D
S
H
E
N
Z
H
E
N
K
E
D
I
D
CT-6321& CT-6322
Figure
Battery Storage Section
1
pH& Conductivity Display
2
Temperature Display
3
CAL Calibration Key
4
HOLD key
5
Power ON/OF Key
6
Electrode fixed collar
7
Electrode Protection Cap
8
* Data hold function for freezing the desired value
* LCD display with pH and temp. OR Conductivity and
temp
* Auto power off in 5 minutes
* Compact size, light weight.
* Power supply by DC 1.5 V battery (LR44, BAT ) x 4 pcs
* Build in temperature sensor, ATC (auto temperature
compensation)
A
E
L
E
C
T
R
O
N
I
C
S
A
E
L
E
C
T
R
O
N
I
C
S
Part Name
http://www.kedida.com.cn/
C
O
.
,
L
T
D
C
O
.
,
L
T
D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CT-6321 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kedida CT-6321

  • Page 1 限 公 司 Pen Meter pH & Conductivity Users Manual CT-6321& CT-6322  Caution Please read the manual carefully before using the meter.  The glass electrode at the bottom of the pen is fragile, please use it carefully after taking off the protection cap. Any ...
  • Page 2 司 深 圳 市 柯 迪 达 电 子 有 限 公 司 SPECIFICATIONS CT-6321 CT-6322 0 to199.9 0 to1999 Measurement Range 0.0 to 14.0 pH Cond 0.0 to 14.0 pH Cond uS/cm uS/cm Resolution 0.1 pH Cond 0.1 uS/cm 0.1 pH...
  • Page 3 Place the electrode into the pH6.8 buffer solution, The pH value will be updated until a stable reading is reached(The data maybe not accurate if the electrode is not be activated) press CAL key for 3 seconds until the text „CAL‟ appear on the display, and release the key http://www.kedida.com.cn/...
  • Page 4 Keep the glass electrode clean, and cover with the protection cap when not use. Be aware of the damage of the electrode when use it. Products should be kept and stored in a cool, dry place that away from direct sunlight. http://www.kedida.com.cn/...
  • Page 5 The buffer solutions (250ml) can be used several times by divided into portions which should be kept in a cool and dry place(20℃-25℃). Never reuse the used portion. The electrode should be fully covered by buffer solution when calibration. http://www.kedida.com.cn/...

This manual is also suitable for:

Ct-6322

Table of Contents