Page 1
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. Cimetrics Inc. B6070 BACnet/IP to Utility Meters User Manual Revised September 2018...
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. Introduction The idea of a pulse meter is to measure Consumption and Demand and timed or aggregated measures derived from these. Consumption is known by various names in various domains - energy usage in electricity, steam usage for steam, water usage for water.
Page 4
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. Then the other four measures are derived from the above along with timing as configured under overall meter configuration…. Demand is the rate of consumption during the demand window period (the time factor in the rate can be deduced from the units exhibited and is set in a fixed fashion to avoid mistakes ).
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. Wiring Instructions Use twisted pair wiring to hook to the pulse outputs of the meters. 18ga twisted pair wiring with (earth) grounded shield is suggested for noise immunity and reliability.
Now disconnect your laptop and connect the B6070 into your BACnet networks. Please note that the B6070 device is always available (does not matter if you have changed the IP address in the TCP/IP and BACnet Configuration page) at the above-mentioned IP address.
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. Router Configuration 1. B3060 web interface overview. Enter B3060’s IP address in your browser. Enter the login “admin” and password written on the label on the bottom of your B3060. Later you can add a new user account if you want, but the “admin”...
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. 2. BACnet Device Settings This page allows you to view/modify BACnet Device settings of the BBMD. Make sure that the Device Instance Number and Device Name are unique across the whole BACnet internetwork. Keep in mind that...
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. 3. BACnet Network Settings Here you specify or modify BACnet network settings or restore them to the factory default settings.
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. 4. BBMD Setting of the BACnet network. This page allows to view or modify BBMD settings attached to the BACnet network. To modify Advanced BBMD settings click on Advanced button – it will open up advanced BBMD parameters. Here you...
Page 11
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc.
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. 5. User Account Settings Here you can change login information. Keep in mind that you can never change your assigned admin password, which is printed on a label on the bottom of the B3060. You can however create one new user...
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. 6. Statistics This page shows statistics for the routing table in B3060, Foreign Devices subscribed to B3060 BBMD and information about B3060 interfaces. Looking at this page you can quickly find out what is happening on your network. You can also...
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. 7. Manage Configuration B3060 allows you to save and then reload the configuration for archive purposes. Note that passwords are not contained in the configuration file. All configuration editing should be done via the B3060’s web interface, not in downloaded files.
B6070 – Cimetrics BACnet/IP to Utility Meters User Manual Cimetrics Inc. 8. Activate Configuration Once changes are made to any configuration on the B3060, the changes get saved only after clicking on the "Confirm" button in the Activate Configuration screen. Clicking on this will initiate a reboot of the device...