Radic8 VIRUSKILLER VK 401 User Manual And Instructions

Radic8 VIRUSKILLER VK 401 User Manual And Instructions

Air steriliser

Advertisement

VK 401
AIR STERILISER
USER GUIDE AND INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Radic8 VIRUSKILLER VK 401

  • Page 1 VK 401 AIR STERILISER USER GUIDE AND INSTRUCTIONS...
  • Page 3: Important Safety Instructions

    Dear Customer Thank you for purchasing the VK 401 Air Steriliser, this is “clean air technology” at its best. This product is packed with power and technology to provide fast and efficient clean air. We hope that you enjoy using your new unit! READ ALL INSTRUCTIONS BEFORE USING YOUR VK 401 When using your VK 401, basic safety precautions should be observed, including the following:...
  • Page 4: Table Of Contents

    USER GUIDE AND INSTRUCTIONS SUMMARY IMPORTANT SAFETY INSTRUCTIONS ..............3 SYMBOLS USED IN THIS MANUAL ..............4 INSTALLATION SAFETY ..................5 KEY PARTS AND COMPONENTS ................7 THE UNIT ....................7 DISPLAY MONITORING ................7 REMOTE CONTROL ................8 CLEANING AND MAINTENANCE ................. 9 CLEANING THE PRE- FILTER ..............
  • Page 5: Installation Safety

    INSTALLATION SAFETY Should the unit emit smoke, No form of water or liquid Do not place any heavy objects unusual odors or make any should enter the unit. Should on the power cord as this may cause a fire and/or an electric strange noises, immediately this occur, immediately switch switch off the unit unplug it.
  • Page 6 Do not alter or modify the plug Use the proper power cable Keep the product away from inflammable gases, liquids, or or cord of this unit as it could and outlet, do not over-load cause a fire or an electric the outlets with several cords other combustible substances, shock.
  • Page 7: Key Parts And Components

    KEY PARTS AND COMPONENTS THE UNIT Filter case Display and monitoring DISPLAY AND MONITORING Remote control sensor Mode (mood lamp) Display and monitoring Power button ON/OFF Fan speed Name Function Remote Control Point your remote control at the sensor in order to use your remote operate the Sensor unit.
  • Page 8: Remote Control

    REMOTE CONTROL 1) Power On/Off 2) Fan Speed Up 4) Mode 3) Fan Speed Down 5) Timer - 6) Timer + 7) Mood Lamp On/Off Name Function Power ON/OFF To switch the unit ON/Off. You will hear a beep sound. Fan Speed Up Increases the fan speed.
  • Page 9: Cleaning And Maintenance

    CLEANING AND MAINTENANCE CLEANING THE PRE-FILTER Ensure that the unit is switched OFF and unplugged. We recommend you check the pre-filter regularly and clean it on a weekly basis. The plastic pre-filter is reusable, to clean it follow the procedure below: a) Open the handle at the top of the unit ①.
  • Page 10: Replacing The Hepa Filter

    Replacing the HEPA filter The HEPA filter is not reusable and must be changed after 2000 hours of use. The display panel will indicate a “FILt” warning. In order to change the HEPA filter refer to Figure 1, and follow the instructions below: a) Open the handle at the top of the unit ①.
  • Page 11: Replacing The Reactor Chambers

    REPLACING THE REACTOR CHAMBERS In order for the VK 401 to remain functional the reactor chambers must be replaced every 8000 hrs. Your unit will indicate that a change is required, “-001” displayed on the LCD. 1. Switch off, and unplug the unit. 5.
  • Page 12: Error Messages

    ERROR MESSAGES Reactor Cell change The lifespan of the Reactor Cell is 8000 hours of use. When this time has passed, the timer on the unit will display with a minus (-). When you see this warning message, it is time to replace the Reactor Cell. UV Lamp malfunction This is an error message that refers to a malfunction of the UV lamps.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Before you call for service, review this list. It may save you time and expense. This list includes co- mmon occurrences that are not the result of defect in workmanship or materials. Problem Possible cause Solution The product The plug is not properly insert- Plug the device into a working grounded will not turn on ed in the grounded outlet.
  • Page 14: Customer Services

    CUSTOMER SERVICES In this manual, you will find a card containing details of your limited warranty. Please contact your distributor if you encounter issues with your unit or to procure replacement filters or reactor cham- ber when these reach their end of life. Damage or malfunction caused by negligence, abuse, unauthorized repairs or use not in accordance with the User Guide will not be covered.
  • Page 16 World Leading Air Sterilization Equipment Sales & Design: First Floor, Columbia Mill, Bedford Street, Bolton, BL1 4BA Tel : +44 (0)1204 238823, E-mail: info@radic8.com, Manufacturer: INBair Korea LTD 3~4F, 72, Jomaru-ro 411 Beon-gil, Bucheon-si, Gyeonggi-do, South Korea E-mail: inbair01@naver.com, www.inbair.com...

This manual is also suitable for:

Viruskiller vk 401

Table of Contents