Summary of Contents for ULTRAPURE Automatic Water Cleaner UPP15
Page 1
Owner’s Manual and Installation Instructions FOR INGROUND AND ABOVE GROUND MODELS WATER QUALITY INC. UltraPureManual12pg34072.indd 1 UltraPureManual12pg34072.indd 1 24.03.16 15:09 24.03.16 15:09...
Table of Contents Important Safety Instructions General Information Performance Guarantee Specifications Installation Location Mounting the UltraPure Water Cleaner Electrical Plumbing Builder Standpipe Install Retrofit Install Installation Instructions External Safety Air Bleed Kit Trouble Shooting & Repair Terms and Conditions of Warranty WATER QUALITY INC.
Do not bury cord. Warning – To reduce the risk of electrical shock, replace damaged cord immediately. ™ Install at least 5 feet from wall of pool using non-metallic plumbing. Install the UltraPure Automatic Water Cleaner ™ no less than 1 foot above maximum water level to prevent water from contacting electrical equipment.
While Ozone is not a disinfectant (to kill algae and bacteria), and does not provide a measurable residual, it is the best Oxidizer for bather-waste removal. An UltraPure UV Ozone generator pays for itself while delivering a bottled-water-like bathing experience.
Automatic Water Cleaner ™ to the pool timing clock so that the UltraPure operates simultaneously with the pool pump or plug your 120V unit into a grounded receptacle. Above ground units come complete with a 120V Piggy back cord. The circuit must be protected by a ground fault circuit interrupter (G.F.C.I.) installed in accordance to electrical code.
Valve is not allowing air to bubble back into the pump basket when the pump is turned off. If the check valve allows air to bubble back into the pump basket, call UltraPure Water Quality Inc. at 877 281 7603.
INGROUND DIAL FLOWMETER INSTALLATION ™ ™ See parts package included with your UltraPure Automatic Water Cleaner Note: Some Dial Flowmeters are equipped with a Quick Connect Elbow. The Quick Connect Elbow is designed to insert the tubing into the elbow and pull back to lock. To remove the tubing, simply push in the release collar and remove the tubing.
External Safety Air Bleed Kit Instructions Effective December 2006, the External Safety Air Bleed Kit (ESABK) comes with every UltraPure ™ Automatic Water Cleaner ™ . The ESABK is not needed or included with the above ground units. This kit is designed to take air from the top of the filter and send it downstream (up to 15) past any and all equipment.
Where the pump has a “lift” more that 3 to 4 feet, order a stronger (than 1 lb.) spring loaded check valve from UltraPure Water Quality Inc. A 3 lb. or 6 lb. spring loaded check valve may be required.
Page 10
Note: When the outside temperature falls below 50˚F (10˚C), the ultraviolet lamp(s) in your ™ ™ UltraPure Automatic Water Cleaner may have difficulty starting. The quartz ozone pro- ducing lamp have mercury vapor inside and the cold temperature causes the mercury to condense and make the lamp(s) more difficult to start.
Call 877 281 7603 to obtain a Return Goods Authorization (RGA) number. No claim will be accepted without an RGA number. b. UltraPure Water Quality Inc. will send out a local area Authorized Service Dealer (ASD) in applicable areas.
Page 12
UltraPure Water Quality Inc. 1155 Appleby Line, Unit E7 Burlington, Ontario L7L 5H9 Canada WATER QUALITY INC. Toll Free: 877 281 7603 www.waterquality.net UltraPureManual12pg34072.indd 12 UltraPureManual12pg34072.indd 12 24.03.16 15:09 24.03.16 15:09...