Minimum Weight
16:
Option 16 sets the minimum weight that the unit will display. LEFT will change the
value of the selected digit and RIGHT will change which digit is selected. For
example if you set the minimum weight† to "000030" and the indicator is sending
"000000" then the display will go BLANK until the threshold value is exceeded.
Maximum Weight
17:
Option 17 sets the maximum weight that the unit will display. LEFT will change the
value of the selected digit and RIGHT will change which digit is selected. For
example if you set the maximum weight to "100000" and the indicator is sending
"120000" then the display will go BLANK until the weight drops below the threshold
value.
Blank Out Character 1
18:
Option 18 sets a character in the data stream to look for to blank the display. For
example if you want the display to blank when over capacity and the indicator sends an
"O", set option 18 to 79.
Blank Out Character 2
19:
Option 19 sets a character in the data stream to look for to blank the display. For
example if you want the display to blank when over capacity and the indicator sends an
"O", set option 18 to 79.
Blank Out Character 3
20:
Option 20 sets a character in the data stream to look for to blank the display. For
example if you want the display to blank when over capacity and the indicator sends an
"O", set option 18 to 79.