Download Print this page

OmniMetrix Hero 40 Amp Tap Commander Installation Manual page 3

Advertisement

If the 4 pin connector
has to be removed in
order to insert the
cable in the conduit,
strip and insert the
wires here according to
the diagram below.
6 PIN
CONNECTOR
1 GREEN
2 WHITE
6 5 4
3 RED
3 2 1
4 BLACK
5
WIRE ENTRY SIDE
6
ON
HERO 2
ACCESSORY
Plug the 6 pin connector into the designated connector on the Hero:
o Hero 1 - TRM6 on the main board.
o Hero 2 - ACCESSORY on the Communication Module
Document No.: IM-1508
Author: T. Robinson/C Fisher
Hero
40 Amp Tap Commander
Connect wires from Power
6 PIN
CONNECTOR
6
5
4
3
2
1
ON
HERO 1
TRM6
Revision Level: 03
Approved By: C. Fisher
3
Installation Guide
Taps here.
Plug 4 pin connector
here as shown.
4 PIN
CONNECTOR
1
2
3
4
ON
TAP COMMANDER
BLUE CONNECTOR
CONN1
Approval Date: 10-JUNE-2020
SDA
SCL
5V
GND

Advertisement