Immax Neo Smart Thermostatic Radiator Valve
Thermostatic Radiator Valves (TRVs) sense the air temperature around them and
regulate the flow of water through the radiator which they are fitted to. They do
not control the boiler.
They should be set at a level that gives you the room temperature you want.
These settings may have to be different in each room, and you should set the
TRVs to suit each room and then leave them to do their job.
Turning a TRV to a higher setting will not make the room heat up any faster. How
quickly the room heats up depends on the boiler size and setting, and the radia-
tor size. Turning a TRV to a lower setting will result in the room being controlled
at a lower temperature, and saves energy.
TRVs need a free flow of air to sense the temperature so they must not be
covered by curtains or blocked by furniture.
ADAPTERS
FUNKCE
M30 x 1.5 Universal Type Head to body connection
LCD display can be clearly read with the background lighting.
Easy for installation
Five buttons make it easy to use.
PID control
7 days program(4 periods/day)
The display shows the set temperature or measured temperature, time.
Temperature display in degrees Celsius.
TECHNICAL DATA
Thermostat operating voltage: 2 x AA1.5 V, alkaline batteries.
Backup storage: EEPROM
Switching options: 7 days programming (4 periods/day)
Frequency: 2.4Ghz
Temperature settings: 5°C ~ 35°C, in 0.5℃
Accuracy: ± 1℃
Control: PID
Thermostat dimensions: 55*69mm
Max Extention: 5.0mm
Color: White
IP protection rating: 20
Certifikace: CE
DISPLAY AND BUTTONS
Low battery indicate
Signal icon
Window opened
Clock and weekday
Current period
Manual mode
Child lock
PRG mode
Away
INITIALIZATION AND ADAPTION
1) Once the battery installed, the TRV display INIL, which means initialization.
2) Wait a moment, the TRV will display AdAP , then please Install the TRV onto
your radiator according to below figures.
3) Press UP button change 0 to 1, which means the TRV will adapt itself to the
stroke of your valve body. To do this, the TRV will now be opened and closed
twice to store the end points.
BATTERY INSTALLATION AND VALVE INSTALLATION( TAKE M30 ADAPTOR
AS AN EXAMPLE)
CHILD LOCK
Press UP and DOWN button at the same time for 5s to lock or unlock the
buttons.
MODE SETTING
Press M button to select Manual mode/Away mode/PRG mode.
CLOCK & WEEKDAY SETTING
Press and hold P button for 5s, set the clock (Min-Hour-Weekday) by pressing
UP and DOWN button, each press of P button will go to next item setting.
7 DAYS PROGRAMMABLE SETTING
After finish the clock setting, continue to press P button to go to PRG schedule
setting.
Set the schedule (Weekday-Period-Start time-Temp.) by pressing UP and DOWN
button, each press of P button will go to next item setting.
Example:
OPEN WINDOW DETECT FUNCTION (OWD FUNCTION)
When the Open Window mode is enabled in the parameter setting, the system
will automatically stop heating when it detects a sudden drop of room tempera-
ture (2°C in 15 minutes as default). This is normally caused when a window or
door is opened without turning off the heating device.
The device will return to the previous mode of operation after 30mins, then dis-
appear. Press any button will exit OWD function during the heating off period.
PAIR WITH GATEWAY
Note: Please make sure you have configure the gateway successfully.
1) Turn HT-10R off by pressing ON/OFF button, then long press M button until it
show a "0 and signal icon", then press UP button.
2) Enter gateway page on the mobile app, and press the button for adding
sub-devices.
3) Click "LED already blink" on the phone.
4) when HT-10R display 3 or signal icon stop moving, means code pairing done.
Press ON/OFF button to return, and press again to turn it on.
PARAMETER SETTING
Turn off the thermostat, Press and hold M and UP button for 3s, until it shows
the item 01, each press of M button will go to next item setting, adjust the
range by using UP and DOWN button.
Smart home devices
UŽIVATELSKÝ NÁVOD
USER MANUAL
Výrobce a dovozce / Manufacturer and importer:
IMMAX, Pohoří 703, 742 85 Vřesina, EU | www.immaxneo.cz | www.immaxneo.com
Vyrobeno v P.R.C.

Advertisement

loading

Summary of Contents for IMMAX NEO LITE

  • Page 1 Five buttons make it easy to use. Výrobce a dovozce / Manufacturer and importer: PID control IMMAX, Pohoří 703, 742 85 Vřesina, EU | www.immaxneo.cz | www.immaxneo.com 7 days program(4 periods/day) Vyrobeno v P.R.C. The display shows the set temperature or measured temperature, time.
  • Page 2 Immax Neo Smart Termostatická hlavice Immax Neo Smart Termostatické hlavice snímají teplotu vzduchu kolem nich a regulují průtok vody skrz radiátor, ke kterému jsou namontovány. Neovládají kotel. Měly by být nastaveny na úroveň, která vám poskytne požadovanou pokojovou teplotu. Tato nastavení mohou být v každé místnosti různé.