table of contents Section In tr od u ctI on ........... 03 Section In stA LL AtIo n I ns truc tIo ns ...... 06 Section op e rAtI on ch ec ks ....... 10 Section Ad j u stM en ts An d ope r At Ion ....12 Section MAIntenAnce And troubL e sh ootIng ..17...
Section In trod uc tIo n thank you for selecting a hydro-rain Wireless rain/Freeze sensor ® (hrc-100-rs-rF). this hydro-rain sensor provides conservation, ® convenience, and flexibility to your fully automatic watering system. After a set amount of rain has fallen, the sensor will send a wireless signal to the receiver and prevent the timer from watering.
Page 4
Section In trod uc tIo n 1. Manual Test Stem pushing downward on stem tests transmitter communication with the receiver. 2. Rain Fall Adjustment Cap range adjusts from ¹⁄ " to 1" (3mm to 25mm). this setting will prevent watering when rainfall reaches the specified setting.
Page 5
8. Sensor Override LED Indicates when manual override is on (see manual override above). 9. Active Sensor LED Indicates when the rain/freeze sensor is overriding the sprinkler timer. 10. Low Battery LED HRC-100-RS-RF Indicates when battery needs to be replaced. Figure 2: receiver...
Section In s tAL L At Ion Inst r uc tIo ns Mounting the Receiver 1. select a location within 6” adjacent to your sprinkler timer (receiver may be located indoor or outdoor). 2. Mount rain/freeze receiver (antenna side up) using screws provided. 3.
Page 7
Section In s tAL L At Ion Inst r uc tIo ns 3. disconnect the common valve wire from the timer, and attach it (using a wire nut) to the yellow (normal closed) wire from the rain/freeze receiver. (see Figure 4) 4.
Page 8
In s tAL L At Ion Inst r uc tIo ns Controller / Timer SENSOR 9 PUMP COM1 COM2 24V 24V To Valve HRC-100-RS-RF Common From Valves Figure 3: Wiring sprinkler timer with sensor terminals without booster pump Controller / Timer 9 PUMP...
Page 9
Section In s tAL L At Ion Inst r uc tIo ns Controller / Timer 9 PUMP COM1 COM2 24V 24V To Valve HRC-100-RS-RF Yellow Pump Start Relay Common From Valves Figure 5: Wiring sprinkler timer with booster pump Wire Nut...
Section ope rAtI on ch e c ks Verify Correct Wiring select a sprinkler station/zone that is visible and in reach of the rain/freeze receiver and sprinkler timer. After manually activating the station/zone, on the sprinkler timer, press the “Manual override” button on the receiver. the top light should indicate that the system is being overridden.
Page 11
Section ope rAtI on ch e c ks Mounting the Transmitter Mount the rain/freeze sensor to a gutter with the provided thumb screw, or to a flat surface, with provided screws, where it will be exposed to direct, unobstructed rainfall (but away from sprinkler spray). the test stem must be upright.
Section Ad j u s tMe nt s And ope r At Ion Figure 6: Attaching sensor/transmitter to gutter or flat surface Rain Sensor the rain sensor keeps the irrigation system from starting or continuing after rainfall quantities of ¹⁄ ", ¼", ½", ¾", or 1".
Page 13
Section Ad j u s tMe nt s And ope r At Ion completely or partially cover the ventilation holes, the hygroscopic discs will dry more slowly. this adjustment can compensate for an “overly sunny” installation location or peculiar soil conditions. experimenting with the vent rings will best determine the ideal vent setting.
Page 14
Section Ad j u s tMe nt s And ope r At Ion Running the Sprinkler Timer when Rain/Freeze Sensor is Active (see Figure 8) 1. Make sure “Active sensor” is the only Led illuminated (on the rain/freeze receiver). 2. push the “Manual override” button–“sensor override” Led will illuminate and “Active sensor”...
Page 15
M t W t F s s stArt InterVAL tIMes eVen 1 2 3 4 d M Y stAtIons dAte MAnuAL cLeAr neXt enter HRC 100 sensor reset rAIn deLAY HRC-100-RS-RF ActIVe/bYpAss Figure 8: running the sprinkler timer when rain/freeze sensor is active...
Page 16
PROGRAM M T W T F S S START INTERVAL TIMES EVEN 1 2 3 4 D M Y STATIONS DATE MANUAL CLEAR NEXT ENTER HRC 100 SENSOR RESET RAIN DELAY ACTIVE/BYPASS HRC-100-RS-RF Figure 9: to stop timer from watering...
Section M A In te n Anc e An d t r ou bLe sh ootI ng Maintenance the two lithium 3V batteries (cr2032) will need to be changed as needed. there is a low battery indicator light on the receiver that tells you when you need to change the battery.
Page 18
If your controller has a rain bypass switch make sure it is in the correct position to allow the sensor to communicate with the controller. F. toggle the manual override switch on the receiver to change status. help: before returning this timer to the distributor, contact hydro-rain ® technical service at: 1-888-hYdrorAIn.