Cutout Dimensions - Fisher & Paykel DCS GDE1 Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

STANDARD CUTOUT
b
a
c

CUTOUT DIMENSIONS

A Height of cutout
B Depth of cutout
C Width of cutout
D Depth of gas supply opening
E Width of gas supply opening
Notes:
When determining a suitable location, take into account concerns such as exposure to wind, proximity to traffic paths,
and keeping any gas supply lines as short as possible.
Locate the unit in a well-ventilated area.
The counter and supporting ledges or deck must be level and flat.
The enclosure should have ventilation holes to prevent gas build-up in the event of a leak. Refer to ANSI Z21.58
Standard for Outdoor Cooking Gas Appliances, Section 1.7 Enclosures For Self Contained LP-Gas Supply Systems.
4
CUTOUT DIMENSIONS
e
d
ventilation
GDE1-30 MODELS
INCHES
MM
10 1/8
257
22 3/4
578
28 1/2
724
4
102
4 15/16
125
INSULATED JACKET CUTOUT
If the unit is to be placed into a combustible enclosure, an insulated jacket is required.
a
CUTOUT DIMENSIONS
A Height of cutout
B Depth of cutout
C Width of cutout
D Depth of gas supply opening
E Width of gas supply opening
F Depth to gas supply opening from front of cutout
G Width to gas supply opening from side of cutout
Notes:
Use only the DCS insulated jacket which has specifically been designed and tested for this purpose.
To purchase access doors and drawers, visit dcsappliances.com
30" access doors model number: ADN1-30
30" access drawers model number: ADR2-30
b
g
e
d
c
f
ventilation
GDE1-30 MODELS
INCHES
11 1/8
23 3/4
34 7/8
4
4
18 1/2
3 1/2
MM
283
603
886
102
102
470
89

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcs gde1-30

Table of Contents