4. INSTALLATION INSTRUCTIONS

Warning
All of the operations described in this section must be
performed by professionally qualified personnel only.
The installation shall be in accordance with National Fuel Gas Code
ANSI Z223.1/NFPA 54 and with CAN1-B149.1 Installation code.
An approved manual gas valve shall be provided by the installer.
4.1. INSTALLATION ON FLOOR OR CEILING
The space heater may be installed:
• on the floor in a stable position
• or suspended by hooking it to the ceiling using cables and/or
chains of an appropriate size and length secured to the four
suspension points.
Warning
Make sure that the ropes and/or chains form an angle not
more than 5° with vertical to the ceiling, that the ropes do
not cross, and that a different rope is used for each hook.
L-L 265.00-BM
EN
The minimum distance from surrounding walls and/or ceiling must
always be at least 1 metre.

4.2. POWER CONNECTIONS

Warning
The 120V unit is fitted with a proper power cord.
The 220V equipment is fitted with a temporary power
cable, used for the final control test at factory. The
temporary power cord must be removed and replaced with
a proper power cord whose type and dimension shall be in
accordance with national rules.
Warning
The power line of the generator must feature an earthlead
and a residual current circuit breaker.
The supply cable must be connected to a switchboard
with sectioning switch.
Warning
When installed, the appliance must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical Code,
ANSI/NFPA 70, and/or the CSA C22.1, Canadian Electrical
Code, if an external electrical source is utilized.
The electrical power cable must be connected in conformity to the
polarity specified on the main terminal board of the electrical panel:
phase (L) and neutral (N).
Warning
If polarities L and N are incorrect, the space heater may
stop a few seconds after it is switched on for the first
time.
Before switching on the heater and, therefore, before plugging it into
the electrical power supply, check that the power supply
specifications are the same as those stated on the identification
plate.