Scilogex SCIP5-20 Operating Instructions Manual

Low-temperature circulator

Advertisement

Quick Links

Low-temperature Circulator
Low-temperature Circulator
Enhanced Low-temperature Circulator
Please read the instructions carefully and use the instrument safely under the
instructions.
12301202
Operating Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCIP5-20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Scilogex SCIP5-20

  • Page 1 Low-temperature Circulator Low-temperature Circulator Enhanced Low-temperature Circulator Operating Instructions Please read the instructions carefully and use the instrument safely under the instructions. 12301202...
  • Page 3 Disclaimer • The intellectual property right of this manual belongs to the Manufacturer, i.e. relevant copyright belongs to the company. • Products of the company are under the patent protection (including obtained patents and patents being applied for). • This manual had been prepared with the attitude of being responsible for the users but cannot guarantee that the contents of the manual are fully correct.
  • Page 4: Table Of Contents

    Table of Contents SAFETY PRECAUTIONS ....................1 PRODUCT OVERVIEW ....................3 ..................... 3 COPE OF APPLICATION ..................4 ECHNICAL PARAMETERS ......................6 OMPONENTS OPERATING INSTRUCTIONS ..................8 ..................8 PACKAGE INSPECTION ........................9 PERATION 3.2.1 Instrument preparation ..................9 3.2.2 Operation panel description ................
  • Page 5: Safety Precautions

    Safety Precautions Caution! • Please carefully read the manual before operating the product, and observe the specifications on safe operation. • Ensure that only trained staff operates this product. Ground protection for safety! • Ensure that the power socket has been properly grounded before operating the product •...
  • Page 6 • Do not operate the circulating pump when there is no circulating liquid or the liquid level is low. • The temperature inside the thermally insulated pot is low at the time of refrigeration. Please donot directly touch the liquid to avoid frostbite. •...
  • Page 7: Product Overview

    Product overview Scope of application • This instrument is designed for use in environments as school, lab, factory, employs fully enclosed compressor unit for refrigeration and microcomputer smart control system and serves to provide low-temperature liquid and low- temperature water bath in order to decrease or to maintain the temperature of the instruments using cooling water and low-temperature liquid.
  • Page 8: Technical Parameters

    Technical parameters Product model Low-temperature Circulator Circulation mode Enclosed circulation No-load minimum temperature -15℃ Temperature adjustment accuracy 0.1℃ Reservoir capacity Temperature adjustment range -30℃ - 30℃ Temperature display mode Type of sensor PT1000 Refrigerating capacity -6.7 ℃ Compressor refrigerant R290 Mixture solution of water and ethylene Internal circulating fluid glycol...
  • Page 9 Product model Enhanced Low-temperature Circulator Circulation mode Enclosed circulation No-load minimum temperature -20℃ Temperature adjustment accuracy 0.1℃ Temperature control accuracy ±2℃ Reservoir capacity Temperature control range -20℃-room temperature Temperature adjustment range -30℃ - 30℃ Temperature display mode Type of sensor PT1000 Refrigerating capacity ℃...
  • Page 10: Components

    Components Low-temperature Circulator Reservoir Display screen Rocker Water outlet switch Water Coupler inlet Serial interface Figure 2-2 Front View Figure 2-3 Back View Enhanced Low-temperature Circulator Display screen Reservoir Rocker switch Water outlet Coupler Serial interface Water inlet Figure 2-4 Front View Figure 2-5 Back View...
  • Page 11 Name Description Display screen Setting parameters Settings and operation information display Reservoir Storage of refrigerated liquid Serial interface Calibration Coupler Provides power supply Rocker switch Power switch Water outlet Output of cooled liquid Table 1 Water inlet Recovery the cooled liquid...
  • Page 12: Operating Instructions

    Operating Instructions Open-package inspection Open-package inspection aims to confirm the completeness of associated parts and the compliance of anti-tilt marks. The packing list is given below: Name Qty. Main unit Power line Operating Instructions Table 2 Connection pipeline If you find any damage on the packing, please specify the damage after receipt. If you find any internal damage after unpacking, please contact your local supplier or manufacturer.
  • Page 13: Operation

    3.2.1 Operation Instrument preparation • The instrument should be placed on a stable surface and well ventilated without any flammables or explosives. • Ensure that the label indicated the correct voltage before connecting the device to power supply. • Ensure that the power socket is grounded properly. •...
  • Page 14: Operation Panel Description

    3.2.2 Operation panel description Figure 3-1 Button name Function Introduction Set the target temperature (upper and lower limits of temperature) Cool Start the compressor to refrigerate Start the circulating pump to circulate the Circulate coolant Adjust the temperature upwards Table 3 Adjust the temperature downwards 3.2.3 Instrument operation...
  • Page 15 After setting the upper and lower limits of temperature, press the ‘SET’ key again to confirm the settings and return to current temperature mode and the LED displays the current temperature of the liquid. When pressing the Cool key, the Cool indicator is lit and wait for 10 seconds before the compressor is started up to start refrigeration.
  • Page 16: Maintenance

    Maintenance Proper maintenance and operation of the instrument in good working state can extend its service life. Keep the instrument dry and clean in routine operations. Clean the outer surface with a non-grinding cleanser and ensure that the entire surface is dry before connecting to power supply.
  • Page 17: Failure Diagnosis

    Failure diagnosis The advanced production technology and testing methods are used for rigorous testing before delivery, to ensure good reliability. In service, the common failures are generally caused by improper operation or setting. If the errors cannot be handled properly, please record the error phenomenon and notify the local dealer, or contact us directly.
  • Page 18 protection conditions and start up after cooling. Improper connection Reconnect the power of fan cable. cable properly. Fan jammed Adjust the fan position. No air output Replace the fan with a Fan blade deformed new one. Replace the fan with a Blower burnt out new one.
  • Page 19: Product Certification

    Product certification We certifies that the construction of this product conforms in accordance to industry standards and ISO9001 standards, and other international standards organizations. Warranty policy According to the manufacturer’s warranty clause, the warranty period of the product is 24 months from the date of shipment under normal service conditions specified in the manual.