Download Print this page

Troubleshooting - Savio High Flow Skimmer 5000 Operating Manual & Specifications

Advertisement

Faults
Pump chmaber runs dry
during operation
Water leak around face-
plate
No skimming action
High Flow Skimmer 5000 Replacement Parts
Code
RC001
RC003
RC004
RC006
RC005A
RC013
RC017
RC009
Possible Causes
Low water level in pond
Weir door closed, stuck or obstructed
Weir not large enough for pump flow
Faceplate screw not tight
Faceplate not sealed properly/
Over-tightened faceplate screws
Weir door closed/stuck/obstructed
Pump is not functioning

Troubleshooting

Remedies
Add water to pond. water level should be bewtween 3/4" above or
below optimum water mark on faceplate
Ensure free movement of weir door / remove obstruction
Reduce pump flow
Install smaller pump
Install larger weir assembly
Use #3 phillips screw rriver to hand-tighten screws snugly
Remove weir faceplate, clean liner of mud or gravel, smooth
wrinkles. Apply silicone, in a continuous bead, connecting all screw
holes on the front-side of pond liner. Then reinstall faceplate over
applied silicone.
Ensure free movement of weir door / remove obstruction
Check operation of the pump and pump screen (if equipped)
Item
Faceplate Screw Pack
Tank
Lid
Baffle
Basket Assembly
Faceplate
Weir Door
Weir Dividers (Pack of 2)
11

Advertisement

loading

Related Products for Savio High Flow Skimmer 5000

This manual is also suitable for:

Hfs5000