2
CONNECT SUPPLIES
Carefully bend copper supplies to meet water supply lines using
the palms of the hands to avoid kinking.
Connect HOT water supply line to LEFT tube, and COLD water
supply line to RIGHT tube using appropriate connectors.
3
INSTALL POP-UP DRAIN
Push TAILPIECE down into TRAP (threaded end up).
Thread LOCKNUT, WASHER and GASKET onto
DRAIN BODY.
Apply a bead of PUTTY to underside of FLANGE.
Feed DRAIN BODY up through SINK and thread
FLANGE fully onto BODY.
Tighten LOCKNUT firmly, keeping the PIVOT ROD
pointed towards the back of the SINK.
Drop STOPPER into DRAIN BODY.
Pull TAILPIECE up and thread tightly
into DRAIN BODY.
Position EXTENSION ROD onto POP-UP ROD and
tighten THUMBSCREW.
4
TEST INSTALLED FAUCET
Move handle down into "off" position and remove AERATOR.
For vandal-resistant FLOW DEVICE, insert KEY teeth into
slots near outlet and turn.
5
HOT LIMIT STOP
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your RELIANT faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove HANDLE, CAP and HOT LIMIT STOP. Follow "A" or "B"
to adjust maximum discharge temperature.
6
SERVICE
AERATOR may accumulate dirt causing distorted and reduced
water flow. Remove AERATOR. Clean AERATOR and FLOW
RESTRICTOR. Replace AERATOR.
If faucet drips, operate handle several times from "off" to "on".
Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply,
then:
Remove HANDLE, CAP, HOT LIMIT STOP and CARTRIDGE.
Clean inlets and MANIFOLD.
Reassemble CARTRIDGE, alternately tightening screws. Replace
HOT LIMIT STOP , CAP and HANDLE. Check flow.
STOPPER
FLANGE
SINK
PUTTY
GASKET
WASHER
LOCKNUT
CLIP
PIVOT
ROD
TAILPIECE
TRAP
PRY UPWARD TO UNLOCK
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
ADJUSTMENT WHEN
WATER IS TOO HOT
HANDLE
SET SCREW
HANDLE
BUSHING
CAP
HOT LIMIT
STOP
CARTRIDGE
SCREWS
CAP
RETAINER
P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c .
© A S A m e r i c a , I n c . 2 0 0 8
OR
Remove one end of CLIP from PIVOT ROD by squeezing
ends together while sliding.
Insert PIVOT ROD into second or third hole in EXTENSION
and reassemble CLIP. (EXTENSION may need to be bent.)
Adjust STOPPER height by repositioning EXTENSION and
tightening THUMBSCREW.
POP-UP ROD
THUMBSCREW
EXTENSION
ROD
DRAIN
BODY
TAILPIECE
TRAP
Turn on water supplies and check connections for leaks.
Operate handle up and down, left and right to flush water lines
thoroughly.
Move handle down to "off" position and replace AERATOR or FLOW
DEVICE.
"A"
PRY UPWARD TO UNLOCK
AND ROTATE CLOCKWISE
ADJUSTMENT WHEN
WATER IS TOO COLD
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800-442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
EXTENSION
ROD
CLIP
PIVOT
ROD
"B"
CARTRIDGE
SEALS
P0P-UP
ROD
7 8 5 1 7 Re v. 1 .1

Advertisement

loading

This manual is also suitable for:

Reliant+ 2385.060Reliant+ 2385.400Reliant+ 2385.460Reliant+ 2385.500Reliant+ 2385.560