Specifications - Monacor IMG STAGELINE FM-910 Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
WARNING
1. While filling up fog fluid, the unit must
not be connected to the mains.
Always disconnect the mains plug
from the socket before filling up!
2. Never add flammable fluids of any kind to the fog
fluid! Explosion hazard!
3 The unit is not splashproof. If fluid gets inside the
unit, it must be checked and cleaned by skilled
personnel before it is operated.
1) Unscrew the tank cap (4).
2) Fill up the tank with fog fluid: Fill up the tank up to
as a minimum and do not add more fluid than up to
the upper marking of the window (8). If any fluid is
spilt, wipe it off immediately with a cloth so that it will
not get inside the unit.
3) Tightly close the tank.
4.2 Setting up the Unit
G
The heat generated within the unit must be dissi-
pated by air circulation. Make sure that sufficient
space is provided next to and above the unit and
that the air vents of the housing are not covered.
G
During operation the fog output nozzle will become
very hot. Always ensure a minimum distance of
50 cm to easily flammable material or material sen-
sitive to heat.
G
The fog stream becomes very hot. Never direct the
fog stream at persons or objects.
Place the unit on a horizontal surface. It can also be
suspended via its bracket (9) [e. g. on a cross arm via
a mounting clip]. For exact horizontal adjustment of the
unit slightly release the screws (5) on both sides of the
bracket, readjust the position of the unit, then retighten
the screws.
WARNING Mount the unit safely and expertly. If the
unit is installed at a place where people
may walk or sit under it, additionally
secure it (e. g. by a safety rope at the
bracket; fasten the safety rope in such a
way that, in the event of a fall, the max-
imum falling distance of the unit will not
exceed 20 cm).
Note: Fog machines will develop condensation around the
fog output nozzle. When selecting a mounting place, take
into account that moisture will accumulate below the nozzle.
4.3 Operation
WARNING 1. The fog machine must be operated
by adults only; never leave it unat-
tended during operation.
2. The housing will become very hot
during operation. Never touch it.
3. Always make sure that there is sufficient fog fluid
in the tank. When operating the unit without fog
fluid, there will be a fire hazard due to overheating.
Besides, the unit may be damaged.
1) Connect the remote control to the jack REMOTE
CONTROL ONLY (1). The magnet on the rear side
of the remote control may be used to adhere to a
magnetic surface.
2) Connect the plug of the mains cable (7) to a socket
(230 V~/50 Hz). Thus, the fog machine is switched
on. It heats up for approx. 5 minutes. During heating-
up, the LED HEATING (2) lights up.
3) When the LED (10) of the remote control and the
LED HEATING FINISHED (3) light up, the unit is
sufficiently heated and fog may be emitted. For this
purpose, keep the button (11) on the remote control
pressed.
1
4
Note: Due to residual fluid in the fog machine, the unit may
still emit some fog after a fog output or after switching off.
4) To switch off, disconnect the mains plug from the
socket. For a more convenient operation it is re -
commended to connect the unit to a socket which
can be switched on and off via a switch.
5) Important! Before transporting the unit, it must cool
down and the tank must be completely empty!
5 Cleaning
For cleaning the outside of the unit, only use a dry, soft
cloth; never use any fluid which may get inside the unit
and cause damage.
Due to the viscosity of the fog fluid and the high
vaporizing temperature, fog machines are susceptible
to clogging. After approx. 40 hours of operation, it is
therefore recommended to clean the unit with a fluid
consisting of 80 % distilled water and 20 % vinegar.
1) Disconnect the mains plug and allow the fog
machine to cool down sufficiently.
2) Completely empty the tank.
3) Fill the tank with the cleaning fluid.
4) Operate the unit with the cleaning fluid in a suffi-
ciently ventilated environment. After the cleaning pro-
cedure, make sure to remove any residual fluid.
5) Refill the unit with fog fluid and create fog for
approx. 3 minutes to remove any acid residues from
the unit.

6 Specifications

Heating power: . . . . . . 900 W
Heat-up time
after switching-on: . . . approx. 5 minutes
Tank capacity: . . . . . . 1 litre
Fog output: . . . . . . . . . approx. 141 m
Power supply: . . . . . . . 230 V~ / 50 Hz
Power consumption: . . 900 VA
Dimensions, weight: . . 260 × 190 × 260 mm, 3.9 kg
Subject to technical modification.
All rights reserved by MONACOR
GmbH & Co. KG. No part of this instruction manual may be
reproduced in any form or by any means for any commer-
cial use.
GB
3
per minute
INTERNATIONAL
®
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

38.6140

Table of Contents