Download Print this page

Lindy 38154 User Manual page 5

50m cat.6 4x4 hdmi & ir matrix extender

Advertisement

User Manual
Reboot command package length is 18byte:
50 56 54 08 0D 00 00 00 00 00 00 00 00 00 00 00 00 0F
Standby Mode command package length is 18byte:
Power on: 50 56 54 08 0B 0F 00 0F 00 00 00 00 00 00 00 00 00 2B
Power off: 50 56 54 08 0B F0 00 F0 00 00 00 00 00 00 00 00 00 ED
Standby Mode query command package is 18byte:
This is a query command which mean you must send query package and then receive an answer.
For example:
Send package: 50 56 54 08 0C 00 00 00 00 00 00 00 00 00 00 00 00 0E
Receive package: 50 56 54 08 0C 0F 00 00 00 00 00 00 00 00 00 00 00 1D
The blue 0F mean Power on, if F0 mean Power off.
IR Command List
NEC code
#define SYSTEM_CODE
#define IR_KEY_POWER
#define IR_KEY_OUTPUT_1_FROM_1
#define IR_KEY_OUTPUT_1_FROM_2
#define IR_KEY_OUTPUT_1_FROM_3
#define IR_KEY_OUTPUT_1_FROM_4
#define IR_KEY_OUTPUT_1_PRE
#define IR_KEY_OUTPUT_1_NEXT
#define IR_KEY_OUTPUT_2_FROM_1
#define IR_KEY_OUTPUT_2_FROM_2
#define IR_KEY_OUTPUT_2_FROM_3
#define IR_KEY_OUTPUT_2_FROM_4
#define IR_KEY_OUTPUT_2_PRE
#define IR_KEY_OUTPUT_2_NEXT
#define IR_KEY_OUTPUT_3_FROM_1
#define IR_KEY_OUTPUT_3_FROM_2
#define IR_KEY_OUTPUT_3_FROM_3
#define IR_KEY_OUTPUT_3_FROM_4
#define IR_KEY_OUTPUT_3_PRE
#define IR_KEY_OUTPUT_3_NEXT
#define IR_KEY_OUTPUT_4_FROM_1
#define IR_KEY_OUTPUT_4_FROM_2
#define IR_KEY_OUTPUT_4_FROM_3
#define IR_KEY_OUTPUT_4_FROM_4
#define IR_KEY_OUTPUT_4_PRE
#define IR_KEY_OUTPUT_4_NEXT
0x00
0x14
0x09
0x1D
0x1F
0x0D
0x1B
0x11
0x17
0x12
0x59
0x08
0x55
0x48
0x5e
0x06
0x05
0x03
0x07
0x40
0x18
0x44
0x0f
0x51
0x1E
0x0E
English

Advertisement

loading