Rs232 Link Settings; Standard System Wiring; O'brien 1100001-101 Bulkhead Coaxial; Burton 5507-1508 Bulkhead - IK OnlinE 3002RS Operating Manual

Electromagnetic receiver modular rov
Table of Contents

Advertisement

ONLINE ELECTRONICS LTD

4.3. RS232 LINK SETTINGS

An RS232 link must be provided between the 3002RS and 3011 EM POD and configured with
the settings below. This link must be 'transparent' meaning that it behaves as if the
connections between the 3002RS and 3011 EM POD were made with wires (as they are in
section 4.1 3002RS ROV SYSTEM DECK TEST) so when any individual byte of data is sent from
the 3011 EM POD it is immediately received by the 3002RS. The data must not be packetized,
buffered, or disrupted in any way otherwise the system may not function reliability.
Baud Rate ............................................................................................................... 9600
Data Bits ...................................................................................................................... 8
Parity ...................................................................................................................... None
Stop Bits ...................................................................................................................... 1
Flow Control ............................................................................................................ None

4.4. STANDARD SYSTEM WIRING

4.4.1. D. G. O'BRIEN 1100001-101 BULKHEAD COAXIAL
Centre ................................................................................................................... Signal
Outer ....................................................................................................................Screen
Connector Shell ......................................................................................................Screen

4.4.2. BURTON 5507-1508 BULKHEAD

1 ............................................................................................................ 0V 3011 POWER
2 .................................................................... +24VDC 3011 POWER (+18VDC to +36VDC)
3 ...................................................................................................................... Not Used
4 ...................................................................................................................... Not Used
5 ....................................................................................................... RS232 Data Ground
6 ................................................................................................... RS232 Data to 3002RS
7 ...................................................................................................................... Not Used
8 ...................................................................................................................... Not Used

4.4.3. FISCHER CONNECTOR

Note that the view of the 3002RS front panel bulkhead is shown for pin designations.
1 ................................................................................ RS232 Data Ground
2 ........................................................................... RS232 Data to 3002RS
3 ............................................................................................... Not Used
4 ............................................ Connected to 1 via RS232 INTERFACE CABLE
4.4.4. 9W D-TYPE CONNECTOR
1 ...................................................................................................................... Not Used
2 ...................................................................................................................... Not Used
3 ................................................................................................... RS232 Data to 3002RS
4 ...................................................................................................................... Not Used
5 ....................................................................................................... RS232 Data Ground
6 ...................................................................................................................... Not Used
7 ...................................................................................................................... Not Used
8 ...................................................................................................................... Not Used
9 ....................................................................................................................... Not used
3002RS_5002_A01