Specifications - Fujitsu AIRSTAGE AUXB004GLEH Operating Manual

Indoor unit (cassette type)
Hide thumbs Also See for AIRSTAGE AUXB004GLEH:

Advertisement

Fog comes out of the indoor unit:
● During Cooling operation, a thin mist may be seen emitted from the
indoor unit. This results from the sudden Cooling of room air by the air
emitted from the air conditioner, resulting in condensation and mist-
ing.
Steam comes out of the indoor unit:
● During Heating operation, the outdoor unit's fan may stop, and steam
may be seen rising from the unit. This is due to the Automatic Defrost-
ing operation. (See page 2)
Water is produced from the outdoor unit:
● During Heating operation, water may be produced from the outdoor
unit due to the Automatic Defrosting operation.
The following conditions may not be breakdowns so
check again.
Doesn't operate at all:
● Has there been a power failure?
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the main power switch set to the OFF position?
● Are you trying to engage in an operation different from the priority
state? (See page 2)
● Is it in standby state? (See page 2)
The operation mode cannot be changed:
● Are you trying to change to an operation different from the priority
conditions? (See page 2)
Poor Cooling (or Heating) performance:
● Did you adjust the room temperature settings (thermostat) correctly?
● Is the air filter dirty? (See page 2)
● Are the air conditioner's inlet port or outlet port blocked?
● Is there a window or door open?
● In the case of Cooling operation, is a window allowing bright sunlight to
enter? (Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?
● Is the fan speed set to low?
Set the temperature lower than the room temperature and use it:
● Temperature does not fall down well. Temperature may not fall down
depending on the room conditions. (While high humidity or the room
temperature is high.) (See page 2)
In the following situations stop operation immediately
and get in touch with authorized service personnel.
● The problem cannot be solved even when the troubleshooting checks
have been performed.
● The FILTER indicator lamp (red) is flashing very fast.
● The wired remote controller or simple remote controller indicate Er
(when connected).
● It has burning smell.

SPECIFICATIONS

AUXB
AUXB
MODEL
004
007
GLEH
GLEH
POWER SOURCE
AVAILABLE VOLT-
198 to 264 V (50Hz) , 198 to 253 V (60Hz)
AGE RANGE
[kW]
1.1
2.2
COOLING
CAPACITY
[BTU/h] 3,800
7,500
[kW]
1.3
2.8
HEATING
CAPACITY
[BTU/h] 4,400
9,600 10,900 14,000 17,100 21,500 27,300
INPUT
[W]
23
25
POWER
CURRENT
[A]
0.17
0.17
SOUND PRESSURE LEVEL (COOLING/HEATING)
HIGH
dB [A] 34/34
34/34
MED -
dB [A] 32/31
32/32
HIGH
MED
dB [A] 30/29
30/30
MED -
dB [A] 28/26
28/28
LOW
LOW
dB [A] 27/24
27/27
QUIET
dB [A] 25/21
25/25
DIMENSIONS & WEIGHT
HEIGHT
[mm]
WIDTH
[mm]
DEPTH
[mm]
WEIGHT
[kg]
14.5
AUXB
AUXB
AUXB
AUXB
AUXB
009
012
014
018
024
GLEH
GLEH
GLEH
GLEH
GLEH
230 V ~ 50/60 Hz
2.8
3.6
4.5
5.6
7.1
9,600 12,300 15,400 19,100 24,200
3.2
4.1
5.0
6.3
8.0
25
29
35
36
84
0.17
0.20
0.24
0.25
0.62
35/35
37/37
38/38
41/41
50/50
33/33
34/34
37/37
39/39
46/46
31/31
33/33
34/34
36/36
43/43
29/29
31/31
32/32
33/33
39/39
27/27
29/29
30/30
30/30
35/35
25/25
27/27
27/27
27/27
30/30
245
570
570
15
17
En-4