  • Page 1 Operation Manual ULTRAPEN ™ PTBT5 Dissolved Oxygen & Temperature Pocket Tester For use with PTBTX2™ App and Your iOS™ or Android™ Mobile Device PTBT5OM-X2 01-20...
  • Page 2: Table Of Contents

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App Table of Contents INTRODUCTION ......................1 FEATURES ........................1 PTBT5 - Layout ......................1 PTBTX2 App Measurement Screen................1 III.
  • Page 3: Introduction

    ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App INTRODUCTION ULTRAPEN Thank you for purchasing the Myron L ® Company ™ PTBT5 Dissolved Oxygen (DO) Pen. This instrument is designed to be extremely accurate, fast, and simple to use in diverse water quality applications. Advanced features include: •...
  • Page 4: Preparing The Do Sensor

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App PREPARING THE DO SENSOR 1. Unscrew the membrane cap from the sensor body by turning in a counter-clockwise direction. 2.
  • Page 5: Step 3 - Choose A Measurement Parameter Setting

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App STEP 3 – CHOOSE A MEASUREMENT PARAMETER SETTING The PTBT5 allows you to select one of three different ways to display DO measurements: •...
  • Page 6: Step 4 - Choose The Ultrapen Mode Setting

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App STEP 4 – CHOOSE THE ULTRAPEN MODE SETTING The PTBT5 has two Ultrapen measurement modes: • HOLD mode (Default) – The PTBT5 displays measurements in real time until the measurement has stabilized, then the App displays the final reading and puts the PTBT5 into Standby mode.
  • Page 7: Step 5 - Set The Location Altitude

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App STEP 5 – SET THE LOCATION ALTITUDE Altitude significantly effects the amount of oxygen that can dissolve in water. As altitude increases, the amount of dissolved oxygen decreases.
  • Page 8: Dissolved Oxygen Measurement

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App DISSOLVED OXYGEN MEASUREMENT I. MEASUREMENT SETUP ALWAYS 1. Makes sure that the DO sensor is filled with electrolyte and allowed to stabilize. 2.
  • Page 9: Ptbt5 Live Mode Measurements

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App III. PTBT5 LIVE MODE MEASUREMENTS 1. If the PTBT5 is OFF, press and release the PEN BUTTON to turn the PTBT5 ON and place it in Standby mode. 2.
  • Page 10: Calibration

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App CALIBRATION I. GENERAL NOTES: • It is recommended that the PTBT5 be calibrated before each series of tests. • Verify calibration if readings are not as expected. If the expected measurement is < 3 ppm, ZERO point calibration is particularly important.
  • Page 11: Zero Calibration

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App III. ZERO CALIBRATION 1. Remove the protective / hydration cap from the DO sensor. 2. Dip the sensor in clean DI, RO, or purified water. 3.
  • Page 12: Air Calibration (Water-Saturated Air)

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App IV. AIR CALIBRATION (WATER-SATURATED AIR) 1. Remove the protective / hydration cap from the DO sensor. 2. Dip the sensor in clean DI, RO, or purified water. 3.
  • Page 13: Water Calibration (Air-Saturated Water)

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App V. WATER CALIBRATION (AIR-SATURATED WATER) EQUIPMENT AND SUPPLIES REQUIRED • 1 ea. – Glass Beaker (≈ 1L). • 1 ea. – Aquarium Air Pump with 1L / min capacity or better. •...
  • Page 14: Temperature Controlled, Full Calibration Procedure

    – Water (DI, RO, or distilled). For ZERO Calibration • 1 ea. – Glass Beaker (≈ 100 ml). • 2 oz. (≈ 59 ml) – 0 ppm Dissolved Oxygen Calibration Solution (Myron L ® Company P/N DOSOL). For WATER Calibration •...
  • Page 15 ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App 11. Tap the Calibration button in the Feature Navigation Bar. 12. The Initial CAL screen will appear. 14. On the Secondary CAL screen, tap the ZERO CAL button.
  • Page 16 ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App D. TEMPERATURE CONTROLLED WATER CALIBRATION 1. Pour 800 ml of DI, RO, or distilled water into the 1L beaker. 2.
  • Page 17: Factory Calibration Reset

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App 19. The PTBT5 will perform the WATER 20. When the calibration is done the App displays the calibration. values and saves a CAL record. 21.
  • Page 18: Exporting Data Files

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App EXPORTING DATA FILES SELECTING AN EXPORT FORMAT: Data records can be exported from the PTBTX2 App as either .csv, .xls or .xlsx formatted files. 1.
  • Page 19: Maintenance

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App MAINTENANCE NOTE: The PTBT5 MUST be recalibrated any time: the DO sensor is replaced; the DO membrane or the electrolyte is replaced, or;...
  • Page 20: Replacing / Refilling The Do Sensor Electrolyte Solution

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App III. REPLACING / REFILLING THE DO SENSOR ELECTROLYTE SOLUTION NOTES: • When excess bubbles have formed inside the electrolyte well, you should refill the electrolyte solution. Minimizing air bubbles inside the electrolyte well will improve accuracy.
  • Page 21: Cleaning The Do Sensor

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App MEMBRANE REPLACEMENT PROCEDURE NOTE: Avoid touching the membrane surface at all times. 1. Remove the older membrane cap from the sensor body by turning it counter clockwise. •...
  • Page 22: Replacing Or Reinstalling The Do Sensor

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App 11. Holding the open sensor sideways or upside down over a sink insert the syringe tip into one of the four openings of the sensor body and thoroughly flush the electrolyte well with clean water (preferrably DI, RO or distilled water).
  • Page 23: Battery Replacement

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App TO INSERT / REINSERT THE DO SENSOR • NOTES: o The O-rings of the sensor are pre-greased for ease of insertion. Carefully remove any packaging from the shaft before installation and handle the sensor by the protective / hydration cap to avoid migration of the grease to the membrane.
  • Page 24: Troubleshooting Guide

    ULTRAPEN ™ PTBT5 Operation Manual Dissolved Oxygen (DO) and Temperature Pen for use with your Mobile Device Running the PTBTX2™ App TROUBLESHOOTING GUIDE Symptom Possible Cause Remedy 1. Close the PTBTX2 App. Ultrapen stays in Standby mode (LED Timing error between the PTBTX2 App 2.
  • Page 25: Specifications

    DO Membrane Caps 5pk, Replenishment Electrolyte 2 oz., Syringe w/Tip Kit, and Instruction Sheet. • RPT5 Full PTBT5 Do Sensor Assembly with 3 DO Membrane Caps (does not include electrolyte solution). MYRON L WARRANTY ® The PTBT5, excluding the sensor and battery, has a one (1) year limited warranty. The DO sensor has a 6-month limited warranty.
  • Page 26 ® MYRON L COMPANY 2450 Impala Drive Carlsbad, CA 92010-7226 Tel: +1-760-438-2021 Fax: +1-760-931-9189 E-Mail: info@myronl.com techquestions@myronl.com www.myronl.com Designed, Engineered and Assembled in the USA. PTBT5OM-X2 01-20...