SPECIFICATIONS Test Result Model No: SR400A Test Date: 20040916 Tester: MO GUO ZHU Test Item Test Conditions Spec Test Result Remark Power Source AC: 230V;50 Hz Idle Current AC 230 V No-Load 5 ± 0.5 across R13 &R15 Power Rated Output.
Page 4
SPECIFICATIONS Test Result Model No:SR400A Test Date: Tester:MO GUO ZHU Test Item 1. Input 2. Signal/Noise 3. Distortion at 4. Distortion at 5. Frequency Sensitivity Rated Response Test Conditions FLAT Rated FLAT Rated FLAT Output FLAT Rated FLAT Output at...
Page 13
Instruments required: 5) Resistive load 4 Ω 800W, 1) Sinusoidal signal generator, 6) Resistive load 8 Ω 300W 2) Dual trace scope, with probe, 3) Digital multimeter, 7) Pink noise from the GM “AUDIO CD”. 4) Variac 0-250 Vac, P.S: Isolate the oscilloscope from earth and adjust the two traces on center of screen in GND position.
TESTING PROCEDURE - Switch ON the LOW amplifier output to 4Ω load resistor and repeat the above booster check verifying more or less the same ± VCC1 conditions and verify that the signal must be symmetrical refer to GND, without detectable distortion and oscillation. Increase the VOLUME pot.
SR 400A 12 inch PLYWOOD black paint MI01870 ZE-fixed rack-nickel plated SR 400A MG00351 black screw-pill M4*16 HK04468 K-front panel combination SR 400A-ALTO-230V ND00367 EV sponge-one side adhesive 2.0t*100*18mmdark black_V1.0 HK01410 K-speaker -bass 12 inch ND00368 EV sponge-one side adhesive 2.0t*378*18mm dark black_V1.0...