LG LB-D1861HL Service Manual page 17

Ceiling duct type air conditioner
Table of Contents

Advertisement

HEAT PUMP
Model : LB-F4261HL/LB-F4263HL
OUTDOOR WIRING DIAGRAM
BK
BK
BR
OR
WH
BK
WH
WH
TM
L
N
52C
RD
220-240V
1ø,50Hz
63H2
POWER SUPPLY
RD
BR
BR
Co
Co
WH
WH
YL
BK YL
BK
PTCR
BK
OR
OR
FMo
FMo
1
2
49FMo
49FMo
S
R
CM
GN/YL
C TH
D.P
TNS
NO
WH
52F1
1
2
3
4
1
3
5
31
T/B1
5
6
A
7
8
B
2
4
6
32
T/B2
WH
WH
BK
BK
YL
BK
YL YL
BK
BL
Cr
WH
WH
BK
CH
RD
BK
BL
RD
C
20SV
RD
GN/YL
3854AP2778F
INDOOR WIRING DIAGRAM
NC
GN/YL
BK
BK
RD
BL
BK
1
WH
2
BR
BL
3
RD
4
TERMINAL
5
GN/YL
BLOCK
6
Tmo
–17–
BR
INDOOR
DRAIN
MOTOR
PUMP
YL
FUSE
250V10A
OPTIONAL
ZONE
CONTROL
EXTRA
PIPE
THERMISTOR
FLOAT S/W
REMOTE
CONTROL
3854A20031X

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents