Use & Operation
6. Turn on Heating Units
1. Plug the heating unit into power outlet.
2. Place power switch in ON position.
3. Press the TIMER button to select desired run time.
We recommend using the 8-hour setting for large loads and the 4-hour setting for
small to medium loads. Always use the included thermometer and thermometer
probe to confirm that the temperature reaches lethal levels. See Heat Treatment
Chart on page 17 for more information.
Safety Note: Each heating unit draws 1500 watts of electrical power. Do not use
extension cords rated below 1500 watts. Each heating unit should be plugged
into a separate circuit, using the included extension cord if necessary.
Warning Light
If the unit overheats, the warning light will
turn on and the unit will begin to beep.
If the warning light is on, turn the heating unit
off by switching the power switch to the OFF
position. Remove the heating unit from the
ventilation tube and allow it to cool for 20
minutes.
The unit overheats when hot air is being
blocked from exiting the heating unit. Before
restarting the treatment, be sure that all
ZappBug enclosure contents are at least
6 inches away from the heating unit to
ensure proper air circulation.
If the problem persists, contact ZappBug customer service.
©2014-2019 ZappBug. All rights reserved. Product specifications subject to change.
(continued)
14
Need help?
Do you have a question about the Oven 2 and is the answer not in the manual?