Controller - Scotsman BC0530 Service Manual

Hide thumbs Also See for BC0530:
Table of Contents

Advertisement

BC0530 Service Manual

Controller

POWER
ALARM
HI WATER
CLEAN
LOW WATER
MAKE ICE
OVERFLOW
FILL
ARM UP
FREEZE
PLATE UP
LOWER
ARM DOWN
HARVEST
BIN FULL
RAISE
FULL RINSE
Machine Status: Displays the position of the Ice/
Clean switch or an Alarm.
Sequence: Displays the current stage of the ice
making process.
Input Status: Displays the status of the individual
sensors for the ice making process.
Fault Codes: The electronic control will monitor
for the following conditions and shut down the ice
machine as required to prevent damage to the
equipment.
>2
If the water tray automatically cycles 3 times
in a row due to a water plate obstruction the controller
will shut down the ice maker and provide LED fault
indicators.
PROGRAMMING PORT
WATER LEVEL SENSOR
RESET
EVAPORATOR TEMP ADJUSTMENT
After 3 consecutive failed attempts at raising the
water plate, the machine will defrost in 5 minutes then
try again. A 2 will flash during the 5 minute defrost.
Machine will shut down if it fails after this defrost
period.
>3
Flashes after 3 consecutive cycles over 35
minutes, But will not shut down the machine. Stops
flashing once a cycle is under 35 min.
March 2020
Page 19
BIN FULL ADJUSTMENT
EVAPORATOR PROBE
BIN PROBE
SWITCH INPUT PORT
DUAL EVAPORATOR JUMPER
WATER RINSE JUMPER
FACTORY USE ONLY!
AC OUTPUTS