Advertisement

Quick Links

X
D
-N1
ORAYA
ATACUBE
User Manual
Version: 1.1 / February 2020

Advertisement

Table of Contents
loading

Summary of Contents for X2E XORAYA DATACUBE-N1

  • Page 1 ORAYA ATACUBE User Manual Version: 1.1 / February 2020...
  • Page 2 This user manual is protected by copyright; all usual rights reserved. Reproduction of this user manual, even in part, is only permitted with the approval of X2E GmbH. Any infringement will result in liability for damages and may result in criminal prosecution.
  • Page 3: Table Of Contents

    User Manual ORAYA ATACUBE Table of contents Introduction ..................... 4 Intended use .................... 4 Delivery contents ..................4 Safety ...................... 5 Safety labels on the device ..............5 General safety instructions ..............5 Connections and controls ................ 6 Installation ....................9 Connecting ....................
  • Page 4: Introduction

     optionally: X RSU(s) ORAYA Check to ensure that the delivery is complete and all parts are in sound condition. If the deliv- ery is incomplete or supplied components are damaged, contact X2E immediately. Do not use damaged components.
  • Page 5: Safety

    User Manual ORAYA ATACUBE Safety Safety labels on the device You find the following two safety labels on the X RSU front side. ORAYA Warning: Hot surface Please note the safety instruction Burning hazard due to hot surfaces (see chapter Connecting). Read this user manual completely before using the device for the first time.
  • Page 6: Connections And Controls

    User Manual ORAYA ATACUBE Connections and controls Front view Back view...
  • Page 7 Service LAN port (F) In case of errors, this port is used as a debugging interface by the X2E support team. USB 3.0 ports (G) Perform a firmware update by using a USB flash drive containing the suitable ISO file.
  • Page 8 User Manual ORAYA ATACUBE The bold settings on the attached label indicate the default configuration: Starting with hardware revision 2.xx, only 2x 10GbE LAN ports are available. Compatibility of GbE standards 1GbE and 10GbE are principally compatible to each other. Use a switch in between if there are connection problems.
  • Page 9: Installation

    User Manual ORAYA ATACUBE Installation Connecting CAUTION Device damage due to overheating Overheating may result in malfunction or destruction of the D -N1. ATACUBE  Do not operate the D -N1 in the vicinity of heat sources. ATACUBE  Ensure adequate air circulation. ...
  • Page 10 User Manual ORAYA ATACUBE PC/Switch  Connect PC or switch via a standard network cable to one of the ports (H-I).  Ensure proper connector seating. Power supply CAUTION Device damage due to wrong power supply A wrong power supply can result in damage or destruction of the D ATACUBE ...
  • Page 11: Xoraya Suite

    User Manual ORAYA ATACUBE Suite ORAYA The graphical user interface X Suite is available to configure and to control the ORAYA -N1. ATACUBE Supported operating systems:  Microsoft® Windows® 7 (32 Bit or 64 Bit)  Microsoft® Windows® 8 (32 Bit or 64 Bit) ...
  • Page 12: Network Settings

    User Manual ORAYA ATACUBE Network settings The X Suite extra tool HWFinder enables access to a web interface to change the con- ORAYA figuration of the 1GbE (H) and 10GbE (I) LAN ports.  Start the X Suite. ORAYA  Click in the Windows notification area.
  • Page 13 User Manual ORAYA ATACUBE  In the menu on the left side, select the category Network configuration.  Click the desired port in the graphic.  Click one of the tabs Port A to Port D.  Activate the Editmode. ...
  • Page 14: Download

    User Manual ORAYA ATACUBE Download The X Suite offers tools to download log data from connected X RSUs. ORAYA ORAYA Hdd-Download  Start the X Suite. ORAYA  Click Hdd-Download. Connect D ATACUBE  Connect the D -N1 to power supply and PC and put the X RSU in (see ATACUBE ORAYA...
  • Page 15 User Manual ORAYA ATACUBE Select log data  Specify start date (a) and start time (b) of the desired time range.  Specify the end date (c). Use the arrows (d) optionally to apply the start date or to jump one day forward or backward. ...
  • Page 16 User Manual ORAYA ATACUBE Statistical data Click the arrow behind Show download statistics (6) to switch between dif- ferent statistics. The symbol displays the current value during download and the average as the process completes. Click Show download statistics (6) to display statistical data graphically. Cancel download ...
  • Page 17: Automatic Download Service

    User Manual ORAYA ATACUBE Automatic download service This X Suite extra tool is a server, which automatically downloads log data from se- ORAYA lected D s (and dataloggers). ATACUBE  Start the X Suite. ORAYA  Click in the Windows notification area. ...
  • Page 18 User Manual ORAYA ATACUBE In the category White list, select the devices for the automatic download service.  Click Refresh the device list (a) to search for D s and dataloggers in the net- ATACUBE work again.  Select the check boxes (b) for all devices that you want to add to the white list. For a selected device, the symbol (c) changes from if it is currently not reachable.
  • Page 19: Update Firmware

    User Manual ORAYA ATACUBE Update firmware  Start the D -N1 web interface (see chapter Network settings). ATACUBE  In the menu on the left side, select the category Firmware Update.  Click Browse… (1) and select a suitable XSWU file. ...
  • Page 20: Cleaning

    Never open the D -N1. ATACUBE  Maintenance and repair must be carried out by X2E personnel only.  In case of malfunctions or damages, please contact X2E via e-mail to get information about returning the D -N1: xoraya-return@x2e.de ATACUBE Transport ...
  • Page 22 X2E GmbH Jahnstrasse 2b 76870 Kandel GERMANY Phone +49 7275 9143 100 +49 7275 9143 109 E-Mail info@x2e.de Internet http://www.x2e.de...

Table of Contents