Download Print this page

Sealey ST80 Instructions page 4

Advertisement

4.9.
Stand-by Mode
4.9.1. To access the system setting pages, press ▲ and▼ buttons simultaneously for 3 seconds.
4.9.2. In stand-by mode the iron will, if not touched during the selected time, cool down to 150° C and remain at that temperature until the iron is
next removed from the rest or any control pressed. At this point it will re-establish the set temperature.
4.9.3. To set the stand-by time: select page 2 by pressing the ▼ button and then press '1'. 'Stb' will flash.
4.9.4. The default setting is 'OFF'. To select a stand-by time: press the ▲ key to increase the period (keeping the button pressed allows the time
to increase rapidly).
4.9.5. Use the ▲ and▼ button to alter the set time or the▼ button to scroll down to 'OFF'.
4.9.6. Press button '1' to store the setting.
4.10.
Automatic Shutdown Mode.
NOTE: automatic shutdown can only be selected if the stand-by time (section 4.9.) has been set. The shutdown time must be greater
than the stand-by time.
4.10.1. To access the system setting pages, press ▲ and▼ buttons simultaneously for 3 seconds.
4.10.2. To set the automatic shutdown time: select page 2 by pressing the ▼ button and then press '2'. 'SdΠ' will flash.
4.10.3. The default setting is 'OFF'. To select a a shutdown time: press the ▲ key to increase the period. Keeping the button pressed allows the
time to increase rapidly.
4.10.4. Press '2' to save the setting.
4.10.5. To reactivate from shutdown mode: switch the soldering station off and restart.
NOTE: When in shutdown mode, a small amount of current is still being consumed. If not being used, switch off and isolate from the
power supply to ensure absolute safety.
4.11.
Touch tone
4.11.1. To access the system setting pages, press ▲ and▼ buttons simultaneously for 3 seconds.
4.11.2. To disable or enable the audible touch tone: select page 2 by pressing the ▼ button and then press '3'. 'bL' will flash.
4.11.3. Toggle either the ▲ or ▼ button to switch the tone on or off.
4.11.4. Press '3' to save the setting.
4.12.
Factory Settings
4.12.1. To access the system setting pages, press ▲ and▼ buttons simultaneously for 3 seconds.
4.12.2. To cancel any manual settings and return to the factory settings: select page 3 by pressing the▼ button twice and pressing the '1' button.
'FAC' will flash.
4.12.3. Toggle either the ▲ or ▼ button to select factory settings or not.
4.12.4. Press '1' to apply.
NOTE: Once the settings have been reset, adjustments can again be made. To retain factory settings, lock the keypad as in section 4.4.
4.13.
Escape
4.13.1 To access the system setting pages, press ▲ and▼ buttons simultaneously for 3 seconds.
4.13.2. To exit the system setting pages: select page 3 by pressing the▼ button twice. Pressing the '2' (ESC) button will return the display to the
main functions.
NOTE: the display will return to the main functions automatically after 10 seconds if no key is pressed.
5. MAINTENANCE
DO NOT open the casing; there are no user-servicable parts inside. In case of malfunction, return to your Sealey dealer or Service
Agent.
5.1.
Cleaning
DO NOT shock the iron tip to remove excess solder; use the dampened sponge wiper.
Clean the casing with a moist, soapy cloth, having ensured that the unit is isolated from the electrical supply.
5.2.
Fault Codes
Fault Code/Fault Description
E-0: Abnormal Heating Alarm
E-1: Abnormal Heating Alarm
E-2: Open Circuit Alarm
Poor Connections
Temperature Display Incorrect
Illegible code
`
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, dispose of it according to local regulations.
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and
Electronic Equipment (WEEE). When the product is no longer required, it must be disposedof in an environmentally
protective way. Contact your local solid waste authority for recycling information.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack Sealey Limited
Cause/Remedy
Transformer damaged. Power chip damaged. Short circuit in soldering iron lead
Open circuit in heating element. Heating element wiring fault.
Heating element damaged. Heating element wiring damaged
Check DIN plug and socket. Check fuse (replace if necessary with fuse of same specification)
Check soldering iron for damage. Recalibrate (see section 4.6.)
Switch off and restart.
Environmental Protection
WEEE Regulations
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
www.sealey.co.uk
01284 757500
sales@sealey.co.uk
01284 703534
ST80 Issue:1 31/03/15

Advertisement