Page 1
DRYING & BLOW-OFF SOLUTIONS www.almeco.eu JETBL ACK SAFET Y PERSONNEL CLEANING STATION Wall-mounted & portable versions Installation, operation and maintenance instructions...
Page 2
Manual content General safety information Cleaning station safety information Your new unit Installation Maintenance & service Spare parts Trouble shooting Waranty Regulations 10. WEEE Recycling & material disposal ALMECO nv Air and water technologies Royennestraat 51, B-7700 Moeskroen info@axongroup.com - www.almeco.eu...
Page 3
DO NOT USE with hazardous materials, the Cleaning Station airstream could move the hazardous materials to other areas. If removing a hazardous material a JetBlack Safety Cleaning Booth will be required for containment. DO NOT misuse this product or use on broken skin, even very low-pressure air can pose a risk! This product is intended to be used for personnel clean down, or for general particle removal.
Page 4
PLEASE NOTE: The hose and gun assembly may arrive detached. If this is the case, simply remove the attached bung from the discharge spigot. Slide the hose clip over the hose cuff, push the hose cuff onto the spigot and tighten the hose clip firmly. ALMECO nv Air and water technologies Royennestraat 51, B-7700 Moeskroen info@axongroup.com - www.almeco.eu...
Page 5
• Secure the cover to the wall with suitable fixings using the two ø7.0mm holes in the sides • Hook the gun onto holder on the cover ALMECO nv Air and water technologies Royennestraat 51, B-7700 Moeskroen info@axongroup.com - www.almeco.eu...
Page 6
There are two plastic brush holders to be removed. Unscrew 2 self-tap screws per brush set • Remove the female receptacle motor lead from the old brushes • Refit new brushes. Assembly is the opposite of removal ALMECO nv Air and water technologies Royennestraat 51, B-7700 Moeskroen info@axongroup.com - www.almeco.eu...
Page 7
Possible Cause Remedy Low Airflow Dirty or contaminated blower filter This item MUST be changed regularly. Almeco recommend the filter is changed every 3 months subject to operating conditions Damaged hose Replace damaged hose Blockage in air ducting Check all ducting and air delivery devices for...
Page 8
• Parts replaced under the warranty become the property of Almeco. • At no time will Almeco be liable for any of the costs to the buyer for labour, transportation or down-time resulting from defective equipment furnished by Almeco.
Need help?
Do you have a question about the Jetblack Safety and is the answer not in the manual?