Agilent Technologies N8262A P Series Demo Manual
Agilent Technologies N8262A P Series Demo Manual

Agilent Technologies N8262A P Series Demo Manual

Modular power meter

Advertisement

Quick Links

Agilent
N8262A P-Series Modular Power Meter
Demo Guide

Advertisement

loading

Summary of Contents for Agilent Technologies N8262A P Series

  • Page 1 Agilent N8262A P-Series Modular Power Meter Demo Guide...
  • Page 2 Introduction This demonstration guide will help you gain familiarity with the basic functions and important features of Agilent N8262A P-Series modular power meter. All demonstration exercises in this guide requires the Agilent N8262A P-Series modular power meter, N1921A (50 MHz - 18 GHz) wideband power sensor (30 MHz bandwidth) and Agilent ESG E4438C Series RF signal generator.
  • Page 3 Table 1. Front panel items descriptions (continue) Item Description CH A and CH B Connector: Sensor input (Type-N connector (f), 50 ohms) operates with Agilent 8480 Series, E-Series (Except E9320 range) and P-Series sensors. Figure 1 shows the dual-channel modular power meter, N8262A. RF ON LED: To indicate the calibrator is ON or OFF.
  • Page 4 Figure 3. P-Series soft front panel Table 3. P-Series soft front panel items descriptions. Keystrokes represented by [ ]. Item Description Preset: To preset the power-meter. An option list of pre-installed measurement confi gurations is presented. DISPLAY up/down: To select the upper or lower measurement window.
  • Page 5 Demonstration Preparation The following instruments and Product type Model number Required option software are required in order to Agilent ESG Vector E4438C fi rmware • 503 or 506 — frequency perform the basic power measurement Signal Generator revision C.04.60 or range GSM900 and time-gating later...
  • Page 6 Demonstration Preparation (continue) Instructions Keystrokes In this demonstration, N8262A is connected via LAN through network. Establish a communication link with the N8262A and P-Series soft front Synthetic Instrument Finder is used to panel: establish the communication link via 1. Run the Synthetic Instrument Double-click on the Synthetic LAN between PC and N8262A.
  • Page 7 Figure 6. N8262A P-Series modular power meter web browser. Instrument on the network can be physically identifi ed by clicking the Toggle ID LED in the web interface. This causes the instrument’s front panel LAN LED to fl ash continuously until Toggle ID LED is clicked again. Figure 7.
  • Page 8 Basic Measurement: GSM900 Instructions Keystrokes To show the ability of the P-Series modular power meter (similar to On the ESG: P-Series power meter) to measure the 1. Setting the frequency and Press [Preset] to preset the instrument. average power in an active GSM900 amplitude [Frequency] [900], {MHz}.
  • Page 9 Basic Measurement: GSM900 (continue) The trace display is stable when Instructions Keystrokes trigger holdoff is set to 4.275 ms On the P-Series soft front panel: (default setting for GSM900). However 1. Set the trigger holdoff to [Trig/Acq], {Settings}, {1 of 2}, {Hold- by reducing the trigger holdoff such off 1.5 ms}.
  • Page 10: Time-Gating Measurement

    Time-Gating Measurement Similar to P-Series power meter, P-Series modular power meter offers extensive triggering facilities for making time-gated measurements. This allows useful average, peak and peak-to-average ratio measurements of complex modulation formats to be taken. This demonstration shows the versatility of the time-gating features of P-Series modular power meter, by setting up four independent times gates on a TDMA signal to measure...
  • Page 11 Time-Gating Measurement (continue) Instructions Keystrokes On the P-Series soft front panel: 4. Confi gure the measurement Upper Window Use the DISPLAY up/down softkey to setup (See Figure 12). highlight the upper window. [Meas]. Use the arrow softkey to highlight and change the value in Feed1: {Combination SINGLE}.
  • Page 12: Ordering Information

    Ordering Information Related Literature The N8262A P-Series modular power meter ordering information. Agilent N8262A P-Series Modular Power Meter and Power Sensors, Product type Model number Data Sheet P-Series modular power meter LXI-C compliance, N8262A Literature Number 5989-6605EN dual channel Agilent N8262A P-Series Modular For further information, refer to: Power Meter and P-Series Wideband Power Sensors, Technical Overview...
  • Page 13 Remove all doubt www.agilent.com Agilent Email Updates For more information on Agilent Technologies’ Our repair and calibration services will get your www.agilent.com/fi nd/emailupdates products, applications or services, please contact equipment back to you, performing like new, Get the latest information on the products and applica- your local Agilent office.