Note: The IA500 has been discontinued, or “end of life,” in production and repair. However, if you need to replace the microphone, speaker or button(s), you may still order replacements through our customer service department. Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186...
Note: Only recommended for use on Bell POTS lines or dial tone provided by ToolVox ; locations with ® private PBX head end phone systems should explore the rest of Code Blue’s speakerphone options. InterAct 500 is a series of line powered speakerphones –...
14 gauge painted steel. It shall measure 9” H x 9” W x 3.5” D and weigh approximately 9 lbs. The faceplate shall provide an overlap to the mounting box to eliminate additional trim work. Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186...
Product wiring diagram reasonably represents current offering and is intended to assist in component identification and service. Earlier product production may have different components and wiring connections. Reference the model and serial number from the unit ID tag and contact manufacturer to confirm replacement part version and availability. Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186...
• 4 - #8 screw (fasteners) 3.72 Ø 1/2" 3/16" Three ½-inch conduit openings are available through the bottom of this panel Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186 www.codeblue.com page 6 of 24 GU-144-M • •...
5. Connect CAT 3 cable to the Ethernet port on the PCB Vertical 6. Attach faceplate to back box Orientation 7. Replace the four faceplate screws Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186 www.codeblue.com page 7 of 24 GU-144-M •...
Electrical Preparation – The unit will need a phone wire (POTS) run through the curb mount with at least 10 inches of wire coming out of the top of the curb mount to connect to the Code Blue phone. A 1/2 inch conduit hole in the back of the unit has been provided for this purpose.
Page 9
IA500 Administrator Guide Specifi cations subject to change without notice or obligation on the part of the manufacturer. Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186 www.codeblue.com page 9 of 24 GU-144-M • • • •...
The IA500 series can be programmed from any touch-tone telephone keypad or through the use of Code Blue’s Unit Programming & Diagnostics (UPD) software. There are basically two modes of operation: Monitoring and Programming. Programming is broken down into two categories: Basic and Audio.
DTMF tones and call the extension or phone number of the Emergency phone. When you dial the phone number to the Code Blue speakerphone you’re trying to reach, you will hear an acknowl- edgement tone or RFA tone to let you know that the phone has picked up and is ready to be pro- grammed.
Page 12
7. Once all phone numbers have been allocated into memory, the operator can modify any combination of the settings once in progamming mode: a. Enter * # (asterisk and pound signs) to close all IA500 programming (Figure 1). Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186...
6. If the command is programmed correctly the unit will emit a single beep; an incorrect entry will trigger a triple beep. 7. Dial 99 - # to reset all programming functions (Figure 1). (Continued on next page) Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186 www.codeblue.com...
Page 14
“6” on the keypad to request the contact closure for the time period pre-programmed. Figure 3 Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186 www.codeblue.com page 14 of 24 GU-144-M •...
3 = no delay Remove any Filter Delay Speed by 4 = 10ms delay dialing: 87-3-# Add a 10ms Delay by dialing: 87- Figure 4 Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186 www.codeblue.com page 15 of 24 GU-144-M •...
Due to variation in telephone line voltage and loop current, changes will affect the quality of sound from and to the IA500. Code Blue has attempted to provide a configuration to match a majority of normal installations. However, manual changes may be required to achieve the best performance.
(as described in Step 6) and then releases. Command Description Command Range Default Example Turns on Auxiliary 00-99 seconds Enter 6 from phone keypad Output Figure 5 Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186 www.codeblue.com page 17 of 24 GU-144-M • • •...
K - 10-24 X ¾ screws (2 each) (High voltage) All wiring must be installed and connected by experienced and certified personnel to meet local and national electrical codes, and will include a service disconnect. Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186...
Note: Only recommended for use on Bell POTS lines or dial tone provided by ToolVox ; locations with ® private PBX head end phone systems should explore the rest of Code Blue’s speakerphone options. Speakerphone programming manuals can be found at: codeblue.com/Support/TechnicalSupport/downloads If the IA500 doesn’t seem to be functioning properly, follow the steps below to test line loop current,...
Note: Only recommended for use on Bell POTS lines or dial tone provided by ToolVox ; locations with ® private PBX head end phone systems should explore the rest of Code Blue’s speakerphone options. InterAct 500-s Single Button & e...
ANNUALLY Replace batteries used with NightCharge , cellular or RF systems (Replace with batteries recommended by the ® communication manufacturer to ensure optimal performance) Code Blue 259 Hedcor Street Holland, MI 49423 USA 800.205.7186 www.codeblue.com page 21 of 24 GU-144-M •...
Page 22
Administrator Guide UNIT SURFACE MAINTENANCE The painted and stainless steel Code Blue models require periodic care to sustain their aesthetic appearance. Units located outdoors are vulnerable to harsh environmental conditions, including UV rays, acid rain, diesel fumes and airborn iron particles (i.e., dust) which over time may cause unit discoloring.
Administrator Guide 14 Warranty Code Blue Corporation provides a limited warranty on this product. Refer to your sales agreement to establish the terms. In addition, Code Blue’s standard warranty language, as well as information regarding support for this product while under warranty, is available at www.codeblue.com/support.
IA500 Administrator Guide Download Information 15 Download Information Code Blue now has a centralized location where you can find installation, setup, information, configuration and operation instructions. ® 1. Centry Administrator Guide: www.codeblue.com/resources/guides 2. CB 1 Series Administrator Guide: www.codeblue.com/resources/guides 3. CB 2 Series Administrator Guide: www.codeblue.com/resources/guides...
Need help?
Do you have a question about the InterAct 500 Series and is the answer not in the manual?
Questions and answers