joining points, and he must comply with specific systems engi-
neering standards. It is mandatory to comply with this instruc-
tion. Any other procedure is prohibited.
The installer must connect the phase wires to the appropri-
ate terminals, and the neutral wire to the specific terminal N. He
must connect the earth wire to the terminal identified by the
symbol
, using care to avoid damaging the components in the
electrical box.
When installation is complete, the sheath passage must be
checked to see if it is watertight, and the cover of the electrical
box must be hermetically closed.
Make sure the three phase wires are connected
properly. Check that the pumps turn in the direc-
tion indicated by the arrow on the flange of the
pump.
I
CONNECTION OF SPOTLIGHTS WITH THE SPA-PAK
During the installation phase, it is necessary to connect the wa-
i
tertight box (
4, detail L) located under the tub (already
connected in the factory with the spotlight(s)) and the two ter-
minals located in the electrical box on the spa-pak.
i
(
2) For connection of the spotlight box with the elec-
trical box, there are two M16 cable clamps (one on the spotlight
box and one on the electrical box).
i
(
3) The connection of the electrical box to the spa-pak
(terminal block M6 on the electrical card) must be made with
a normalized cable 2x1.5 mm
ly protect in the section that goes from the spa to the spa-pak.
Once the connections have been made, the installer must
check that the cable clamps are watertight, and then hermet-
ically close the watertight box located under the tub and the
cover of the electrical box.
I

CONNECTION OF COMPENSATION TANK

WITH SPA-PAK

The compensation tank has three level switches and a sole-
noid valve of 3/4" (for topping off water), already wired in a
i
watertight box (
4, detail F).
The devices are connected as follows:
EVC filling solenoid valve
L sic safety level switch
L min minimum level float switch
L max maximum level float switch
i
(
2) For connection of the devices with the electrical box
on the spa-pak, there are two sheath passage fittings measur-
ing 1/2"x Ø16 mm (one on the box fixed on the compensa-
tion tank and one on the electrical box).
2
, which the installer must adequate-
i
(
3) The connection to the electrical box of the spa-pak
(terminal block M4 for the level switches; terminal block
M5 for the solenoid valve) is to be made with eight normal-
ized wires with a minimum cross-section of 2x1.5 mm
the installer must protect with a section that is adequate for the
existing sheath passage fittings.
Once the connections have been made, using care to comply
with the numbering of the two respective terminal blocks, the
installer must check that the sheath passage and the sheath
are watertight, and then hermetically close the watertight box
of the compensation tank and the cover of the electrical box.
I

CONNECTION OF PNEUMATIC PUSH BUTTONS

WITH THE SPA-PAK

To activate some of the functions from the tub (hydromassage, fan,
blower, water heater), the pneumatic push buttons must be installed,
obviously as close as possible to the spa so that they can be ac-
cessed by the person using the spa. It must however be possible to
inspect the push buttons in the location where they are installed.
First of all, the pneumatic push buttons must be connected
to the corresponding junction box (
small plastic tubes provided.
NOTE: the box can be installed under the spa, or outside it,
but not more than 2.5 metres from the push buttons.
i
(
2) For connection of the push button box with the electri-
cal box on the spa-pak, there are two M16 cable clamps (one
on the push-button box and the other on the electrical box).
i
(
3) The connection of the electrical box to the spa-pak
(terminal block M8 on the electrical card) must be made
with a normalized cable 6x0.75 mm
adequately protect in the section that goes from the push but-
ton box to the spa-pak.
Make sure to match the connections on the terminal block
with those on the terminal block on the electronic card , es-
pecially the connection of the common wire C.
In addition, the installer must check that the cable clamps are wa-
tertight, and then hermetically close the watertight box connected
to the pneumatic push buttons and the cover of the electrical box.
I
Possible connection of the spa-pak with the pri-
mary circuit of the heat exchanger
The spas of the Experience range, instead of a water heater,
may be equipped with a plate heat exchanger. In this case, the
water of the spa that circulates in the secondary circuit of the
heat exchanger must be heated with hot water that is circulated
in the primary circuit of the heat exchanger (for example by
means of a circulation pump).
Circulation of hot water in the primary circuit must be con-
trolled by the electrical box installed on the spa-pak, by con-
necting the circulation pump, via a remote switch, to the re-
spective terminal on the electronic card of the electrical box.
See below.
If the building has a water heating system, with a circula-
tion pump that is always in operation, it is possible to create
29
2
, which
i
4, detail G), using the
2
, which the installer must

Advertisement