Pentair STA-RITE VSD EASY 09 M/M Instruction Manual page 17

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
CONFIGURATION
The configuration menu allows adjustment of the maximum intensity (A), the minimum frequency of rotation of the pump (FL) and the
direction of rotation (RS). Perform the following steps:
DISPLAY
To start the configuration sequence press the
is stopped.
Using the buttons
thermal protection.
For VSD Easy 9 M/M enter a value between 0 and 9A, the default value is 9 A.
For VSD Easy 6 M/M enter a value between 0 and 6 A, the default value is 6 A.
For VSD Easy 10 M/M enter a value between 0 and 10 A, the default value is 10 A.
This value is indicated on the technical data plate of the pump or pump motor. Press the button
Only for the VSD EASY M/T models.
With the button
Use the buttons
The value ranges from 15 and 35 Hz. The default value is 30 Hz. Press the button
to validate.
The system is configured. Press the button
LOGS OF FUNCTIONS AND ALARMS.
In manual mode with the pump stopped simultaneously press the keys
use the button
ENTER to proceed to enter the log Once the last log has appeared, the display will show the main menu by pressing
ENTER. Display sequence:
HOUR COUNTER (HF). Number of operation hours
STARTS COUNTER (CF). Number of operating cycles, one cycle is a start and a stop.
CONNECTION COUNTER (Cr). Number of connections to the power supply.
WATER INSUFFICIENCY ALARM COUNTER (A1). Number of alarms due to insufficient water.
OVERCURRENT ALARM COUNTER (A2). Number of alarms due to overcurrent.
PUMP CANCELLED ALARM COUNTER (A3). Number of alarms for pump cancelled.
TEMP ALARM COUNTER. EXCESSIVE (A6). Number of alarms due to overheating.
SHORT CIRCUIT ALARM COUNTER (A7). Number of short circuit alarms.
OVERVOLTAGE ALARM COUNTER (A8). Number of alarms due to overvoltage
LOW VOLTAGE ALARM COUNTER (A9). Number of alarms due to low voltage.
The logs remain in memory even during disconnection from the mains
Note: For values higher than 2 digits, the figures will follow one after another on consecutive screens after pressing ENTER. For
example, how to indicate 10,234 overcurrent alarms:
DESCRIPTION
set the value of the rated current of the pump to enable the
ENTER to validate.
START/STOP check the direction of rotation of the pump. With the keys
(0/1) reverse the direction of rotation. Press
to increase the lower limit of the rotation speed of the pump motor.
MENU button for 3 seconds when the pump
ENTER to validate.
ON/OFF to leave the manual operation mode.
MENU +
for 3s to obtain the functions and alarms keys,
BUTTON
MENU for 3s
ENTER
ENTER
ENTER
ENTER
ON/OFF
EN
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sta-rite vsd easy 6 m/tSta-rite vsd easy 10m/t

Table of Contents