  • Page 2 Before reading this manual This operation manual contains basic instruction on installing and using DirectIP™ Gigabit PoE Switch, an IDIS product. Users who are using this product for the first time, as well as users with experience using comparable products, must read this operation manual carefully before use and heed to the warnings and precautions contained herein while using the product.
  • Page 3 FCC Compliance Statement THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS.
  • Page 4 Safety Precautions Do not use the product in an excessively hot (50°C or above), cold (0°C or below), or humid environment. ● Presents a fire hazard. Set up the product in a shaded area providing protection against exposure to direct sunlight and maintain an even ambient temperature.
  • Page 5 Safety Precautions If there is a strange noise or smell coming from the product, unplug the power cable and contact the service center right away. ● Presents fire and electric shock hazards. Failure to comply can lead to minor injury and/or product Caution damage.
  • Page 6: Table Of Contents

    Table of Contents Part 1 - Introduction Product Features Accessories Overview Front Panel Rear Panel Part 2 - Installation Grounding Port Connection DirectIP™ NVR Connection DirectIP™ Camera Connection Cascading Port Connection Warnings and Tips Part 3 - Miscellaneous Supported SFP Transceiver Module List Troubleshooting Specifications...
  • Page 7: Part 1 - Introduction

    Part 1 Introduction Product Features This multi-port, DirectIP-based, and IEEE 802.3af and IEEE 802.3at Power over Ethernet-enabled Gigabit Switch offers the following features: ● DirectIP – Automatic network IP configuration – Individual port data transmission to DirectIP NVR (Network Video Recorder) ●...
  • Page 8 Part 1 - Introduction DirectIP Gigabit PoE Switch Connection Diagram DirectIP Switch SFP Module...
  • Page 9: Accessories

    Part 1 - Introduction Accessories Upon unpackaging the product, check the contents inside to ensure that all the following accessories are included. ● DH-2328PF ● Power Cable ● Installation Manual ● Rack Mount Brackets: 2EA ● Screws for Mounting Bracekts : 6EA ●...
  • Page 10 Part 1 - Introduction 10/100/1000 Base-T Ethernet Ports (Auto Detection) (RJ-45 Service Ports) Port numbers 1 to 24 are PoE-enabled RJ-45 ports. These are PoE-enabled RJ-45 ports. Connect a network camera to one of these ports. • PD network cameras will receive power over the signal line, without the use of an external power source.
  • Page 11 Part 1 - Introduction Console Port Console port is not supported. PoE Mode Switch Button Press PoE Mode Switch-Over Button longer than two seconds to switch the display mode between PoE modad and port rate mode. LED Status Indications Status Color Description Device is not receving power.
  • Page 12: Rear Panel

    Part 1 - Introduction Rear Panel Grounding Terminal Power Connector 1 Power Connector Connect the power cable to this connector. This product does not feature a separate power on/off button and will turn on the moment power is supplied. • Organize the power cable so that it will not cause people to trip over or become damaged from chairs, cabinets, desks, and other objects in the vicinity.
  • Page 13: Part 2 - Installation

    Part 2 - Installation Grounding The system must be grounded before use. Refer to the explanation below: Connection Remove the grounding screw located on the back of the product, next to the power switch. Thread the grounding screw through a grounding wire provided and screw it back in place. Connect the other end of the grounding wire to the rack or any other grounding point.
  • Page 14: Port Connection

    Check the SFP uplink port LED's status and DA-MC1101's TX and FO LED status and verify that a normal connection has been established. DA-MC1101 (10/100/1000BASE-T to Gigabit Fiber Media Converter) is an IDIS converter unit designed exclusively for gigabit network needs.
  • Page 15: Directip™ Camera Connection

    Part 2 - Installation DirectIP Switch SFP Module DirectIP™ Camera Connection Connect the system's RJ-45 service port to the network camera's RJ-45 port using a UTP cable. Check the RJ-45 service port LED's status and verify that a normal connection has been established.
  • Page 16: Cascading

    Part 2 - Installation Cascading Via UTP Cable Connect the RJ-45 uplink ports of system 1 and system 2 using a UTP cable. Check the RJ-45 uplink port LED's status and verify that a normal connection has been established between the two products. Remote Connection via an Optical Cable Insert SFP modules into the SFP uplink slots of system 1 and system 2 and then connect the modules using a fiber optic cable.
  • Page 17: Port Connection Warnings And Tips

    Part 2 - Installation Port Connection Warnings and Tips • Keep the UTP cable length to less than 100m. • This product uses lasers to transmit signals via its SFP uplink ports. These laser beams are Class 1-compliant beams that pose no threat to human eyes if operating normally. It is, however, recommended that you do not look directly into the ports while the system is powered on.
  • Page 18: Part 3 - Miscellaneous

    Part 3 - Miscellaneous Supported SFP Transceiver Module List The system's SFP ports support the following types of SFP modules: Diameter Wavelength Standard Length Mode Connector SFP Module (um) (nm) 50/125 500m Multi Finisar 1000BASE-SX FTLF8519P3BNL 62.5/125 300m Multi Finisar 1000BASE-LX 9/125 1310...
  • Page 19: Troubleshooting

    Part 3 - Miscellaneous Troubleshooting Problem Check ● Check the power cable. Power LED will not turn on. ● Check the power supply status to the outlet the power cable is connected to. The system shuts down shortly after Check power connection components for electric powering on.
  • Page 20: Specifications

    Part 3 - Miscellaneous Specifications Model DH-2328PF 1Ghz single core System Memory 512MB SDRAM, 256MB Flash Switching Capacity 56Gbps 24 RJ-45 Connectors Copper Service Port (10/100/1000BASE-T) Optical Uplink Port 4 SFP Slots (1000BASE-X) Console Protocol 1 RJ-45 Connector 100-240V~, 50-60Hz, Power Input 5.5A~2.5A...
  • Page 21 OPEN SOURCE GUIDE b) You must cause any work that you distribute or publish, that in whole or in GNU General Public License (GPL) part contains or is derived from the Program or any part thereof, to be licensed as a whole at no charge to all third parties under the terms of this License. c) If the modified program normally reads commands interactively when run, GNU GENERAL PUBLIC LICENSE you must cause it, when started running for such interactive use in the most...
  • Page 22 OPEN SOURCE GUIDE you (whether by court order, agreement or otherwise) that contradict the the version number 2.1.] conditions of this License, they do not excuse you from the conditions of this Preamble License. If you cannot distribute so as to satisfy simultaneously your obligations The licenses for most software are designed to take away your freedom to share under this License and any other pertinent obligations, then as a consequence and change it.
  • Page 23 OPEN SOURCE GUIDE 0. This License Agreement applies to any software library or other program 4. You may copy and distribute the Library (or a portion or derivative of it, under which contains a notice placed by the copyright holder or other authorized Section 2) in object code or executable form under the terms of Sections 1 and 2 above provided that you accompany it with the complete corresponding party saying it may be distributed under the terms of this Lesser General Public...
  • Page 24 OPEN SOURCE GUIDE 7. You may place library facilities that are a work based on the Library side-by- 15. BECAUSE THE LIBRARY IS LICENSED FREE OF CHARGE, THERE IS NO side in a single library together with other library facilities not covered by this WARRANTY FOR THE LIBRARY, TO THE EXTENT PERMITTED BY APPLICABLE LAW.
  • Page 25 OPEN SOURCE GUIDE Permission to use, copy, modify and distribute this software and its THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER ``AS IS'' AND ANY documentation for any purpose and without fee is hereby granted, EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE provided that the above copyright notice appears in all copies and IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR that both that copyright notice and this permission notice appear in...
  • Page 26 OPEN SOURCE GUIDE without specific prior written permission. derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER ``AS IS'' AND ANY CONTRIBUTORS ``AS EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR...
  • Page 27 OPEN SOURCE GUIDE OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED used. This can be in the form of a textual message at program startup or in documentation (online or textual) provided with the package. ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR Redistribution and use in source and binary forms, with or without modification, TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF are permitted provided that the following conditions are met:...
  • Page 28 OPEN SOURCE GUIDE Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. Redistributions in any form must be accompanied by information on how to obtain complete source code for the DB software and any accompanying software that uses the DB software.
  • Page 29 IDIS Co., Ltd. For more information, please visit at www.idisglobal.com...

Table of Contents