Download Print this page
Hide thumbs Also See for Icona Manager:

Advertisement

Quick Links

EN
USER MANUAL
Icona Manager
art. 20003310W
art. 20003310B

Advertisement

loading

Summary of Contents for Comelit Icona Manager

  • Page 1 USER MANUAL Icona Manager art. 20003310W art. 20003310B...
  • Page 2 • for the systems, by qualified technical personnel. • Comelit Group S.p.A. accepts no liability for any purpose other than the intended use, or failure to observe the indications and warnings contained in this manual. • Comelit Group S.p.A. reserves the right to change the information provided in this manual at any time and without prior notice.
  • Page 3 DESCRIPTION .................... 26 SOFT-TOUCH KEYS ................4 Instant ....................26 Scheduled ....................26 CONNECTION TO THE HOME AUTOMATION BUS VIA COMELIT HUB ..5 Conditioned ................... 26 MAIN MENU ......................5 ENABLING/DISABLING A SCHEDULED OR CONDITIONED SCENARIO ..MENU ICONS ....................5 Alarm menu icon ..................
  • Page 4 DESCRIPTION Microphone 4.3" touch screen RFID key sensor Micro SD card Function keys Soft-touch function keys FUNCTION KEYS Programmable key: /+ (d rivacy silent mode octor door opening upon call • SILENT mode is used to deactivate / reactivate the ringtone for calls originating from the external unit and the switchboard.
  • Page 5 Comelit Hub NO ACTIVE ELEMENTS AT LEAST 1 ACTIVE ELEMENT If you are connecting to the home automation bus via the Comelit Hub, you need to update Icona Manager to firmware version 3.0.0 or later, EE 2.7.1 or later. „ Check the current version in the menu Setup/General parameters/Information.
  • Page 6 Favourites bar „ Select the icon to change the order of the links in Favourites; confirm. „ Select the icon to create a link to the selected function in the favourites BAR. „ Select the icon to delete the link; confirm. 5|30 „...
  • Page 7 AREA STATUS INDICATORS [2.] Use of Icona Manager in SimpleSafe systems System off Insert total Insert partial Alarm activated across the „ Update firmware art. 20003310W to version 2.4.2 or later. Alarm deactivated Alarm partially activated entire system „ Verify model and firmware version of the Vedo control panel.
  • Page 8 RESET ALARMS • To view images and videos, at least one camera must be connected and associated with an area of the alarm system. The alarm system can be reset in any of the following 3 ways: • The functions can be configured and activated via Safe Manager. •...
  • Page 9 „ Select the desired area. # OPTION B „ Access the Alarms menu and then press the icon to AL ARM access the Options menu. Area 1 Are a 2 „ Press the CUSTOMISED ACTIVATION icon. Are a 4 Area 3 Are a 4 „...
  • Page 10 SELF-IGNITION „ Select the desired zone for partial activation and the activation type. • IMM = immediate • RIT = delayed The activated area is highlighted in green; the type of activation performed is also indicated. Camera 1: In communication ALARM A re a 1 Are a 2...
  • Page 11 „ Press icon [A] with the activation name to launch the corresponding scenario. ALARM You can add links to the activation controls in the alarm homepage. Omitted „ Press icon [B] to add the activation control to the alarm Isolated function homepage.
  • Page 12 Exit controls Alarm settings-Exit controls ALARM This function enables you to change the status of the exits in the system. Robbery Flooding ALARM Exit 1 Medical Exit 2 Exit 3 Exit 4 ALARM Event1 Event2 „ Press the icon to add the SHORTCUT to the homepage of the alarm function.
  • Page 13 Change PIN „ Swipe with your finger to the left or right to move between the phone book entries. Setup-Anti-intrusion-Change pin The CHANGE PIN panel allows you to edit or delete the pin codes associated with the various users. „ Press the icon to edit the value of the corresponding entry.
  • Page 14 Timer » Function ACTIVE Setup-Anti-intrusion-Timer » The system confirms and updates the settings. This option allows you to enable/disable the alarm system activation timer. Installer menu Setup-Anti-intrusion-Installer menu ALARM SETUP The option enables/disables installer mode in the system parameters Timer 1 of the control panel.
  • Page 15 The function allows you to manage (by activating or deactivating) the „ Enter the Safe Manager alarm control panel parameters. alert sounds of the device. The required parameters vary according to the method used to connect Icona Manager to the home automation bus. ALARM SETUP Timer ALARM SETUP...
  • Page 16 DOOR ENTRY MONITORS DOORS OPEN Door entry monitors-Doors open This function allows you to examine a directory of doors to check their status (open/closed). (Paragraph "Doors directory" on page 48) „ Press the icon to access the door entry monitors menu.
  • Page 17 MESSAGES Door entry monitors-Messages VIDEO MEMORY This function allows you to manage the ViP messaging system of the device. „ Press the icon to access the dedicated sub- menu. 01/01/2020 17:30 01/01/2020 17:45 01/01/2020 20:45 MESSAGES Previously viewed video recording Common messages New video recording resolution Video messages...
  • Page 18 MULTIPLE ADDRESSES ADVANCED FUNCTION SCHEDULING Door entry monitors-Multiple addresses The function allows you to configure the device to manage multiple addresses, thereby permitting the reception of calls directed to other Some icons allow you to identify the presence of a schedule ViP devices.
  • Page 19 OTHER / LIGHTS / IRRIGATION / AUTOMATIONS room 1 room 3 room light 1 light 2 Alarms light 3 Alarms Video System Climate light 4 Thermo 20,0° Other Blinds Lights 17:36 02/01/20 Irrigation Automations Loads Selected room Devices in the selected room „...
  • Page 20 TIME STATE TIME STATE 05:00 05:00 PROG PROG 09:00 09:00 Days of the week bar Time/Status table Once you have returned to the main page, you can copy the Programming mode icon programmed activity from one day to another: Copy program icon Programming ON/OFF icon „...
  • Page 21 LIGHTS „ Press the cursor and drag it to set the desired timer value. YOU can also press and hold on a point of the arc to move the cursor to the DIMMABLE LIGHTS required point. „ You can set the timer with precision by pressing the buttons.
  • Page 22 DIMMABLE LIGHTS WITH PRESENCE SENSOR ICON - KEY Time column Status column (ON/OFF) Brightness setting column Presence Presence „ Set the times and status as described in the paragraph sensor sensor deactivated activated "FUNCTION SCHEDULING" on page 19 „ Set the brightness desired in the same way. Programmed scheduling is deactivated Minimum...
  • Page 23 RGB LIGHTS SCHEDULING „ Hold pressed the desired ROOM or DEVICE to open the thermostat 1 thermostat 2 thermostat 3 advanced panel, then select the option SCHEDULING to open the corresponding panel. 24,7° 25,5 ° TIME 09:00 PROG 09:45 100% List of climate zones „...
  • Page 24 MANUAL FORCING Days of the week bar Programming mode Copy program It is possible to set a different setpoint for a specific period of time Graph mode (hours or days). Start time End time Temperature/humidity setpoint „ Press the icon to access the climate forcing function. „...
  • Page 25 LOADS Selected meter Information about the time period (day/month/year) and the relative energy consumption. From the loads section you can activate or deactivate the automatic Real-time consumption shutdown function for the loads monitored by the home automation Change units of measurement/currency system.
  • Page 26 Instant scenario 10/03/15 Instant scenario with function linked to the anti-intrusion system 10.4kWh PLAY&STOP scenario 880W Function only available if Icona Manager is connected to the home automation bus via Comelit Hub 20003150. 0.00 Scheduled SCENARI CONSUMPTION/PRODUCTION COMPARISON scenario 1 If the system includes production units (e.g.
  • Page 27 „ Press the icon to access the function. ENABLING/DISABLING A SCHEDULED OR CONDITIONED SCENARIO Audio broadcast Function not available if Icona Manager is connected to the home automation bus via Comelit Hub 20003150. Audio broadcast 1. Player_1 „ Swipe your finger up or down to view all the available menu 1.
  • Page 28 PLAYER SCREEN PLAYLIST SCREEN „ Short press on a player to open the play panel. „ Scroll to the left to display the PLAYLIST page Player 1 Playlist 1. Song_1 Player 1 Playlist Library Artist - Album 1. Song_1 Artist - Album 2.
  • Page 29 You can enter up to 100 audio broadcast actions in a home automation scenario. Function only available if Icona Manager is connected to the home automation bus via Comelit Hub 20003150. Rules configured previously on Comelit Hub can be enabled/disabled.
  • Page 30 SETUP If the system includes a Vedo control panel, the language is automatically set to that used by the control panel itself, regardless of the language selected. „ Press the icon to access the setup menu. Setup Lock keypad and touch screen Setup-General parameters-Lock keypad and touch screen „...
  • Page 31 IP: 169.254.156.131 (A/16) External call MAC: 00:25:29:03:AA:BB GW: 192.168.1.1 Valuta ID: 00000001, SUB: 0 Intercom call ICONA MANAGER K CO2 Floor door call Visualizzazione Alarms „ Select the desired function. „ Press the icon to exit the screen. VIDEO DOOR ENTRY SETUP...
  • Page 32 Soft touch keys WIDGETS Setup-General parameters-Soft touch keys Setup-Widgets The menu allows you to select which widgets are to be shown on the This function allows you to decide how to activate the device's soft HOME page. touch keys (short press/swipe). SETUP Press key Meter 1...
  • Page 33 CONSUMPTION „ Option SELECTED Setup-Consumption The consumption menu allows you to manage various options related √ By selecting the CUSTOMISED option, you can assign a to energy consumption. customised name to the currency consisting of 3 letters/digits. » The available options are: Toolbar / Currency / K CO2 / Display / Tariffs / Limits / Reset / Settings.
  • Page 34 „ Swipe your finger up or down to view all the available menu You can select the day/s to be modified by pressing the corresponding options. icon on the top bar. » The selected day/s will be highlighted in red. „...
  • Page 35 Settings „ Select the day of the week to copied in the band at the top. Setup-Consumption-Settings » The source day is highlighted in yellow. This function allows you to change certain characteristics of the „ Press the icon to copy the programme, then select meters installed.
  • Page 36 From the menu you can create, rename, edit, move or delete one or more scenarios in one of the three available categories. The scenarios created via Comelit Hub and via system managers other than Icona Manager cannot be edited! Scale factor...
  • Page 37 Creating new scenarios SCENARIO „ Press the icon to create a new scenario. room 1 room 2 room 3 room 4 Confirm Scenario action delay „ Assign a name to the scenario, then confirm. „ Select the desired status and press the icon to confirm. SCENARIO •...
  • Page 38 Function only available if Icona Manager is connected to the home automation bus via Comelit Hub 20003150. Rename Move „ Deselect the icon if the scenario should only be available on the device. Edit Delete „ Select the icon if you also want to make the scenario available to other system managers and apps.
  • Page 39 Scheduled EDIT SCENARIO • Setup-Scenarios-Scheduled „ Press the icon to modify the functions associated with the selected scenario. SCENARIOS Scheduled 1 SCENARIO Scheduled 2 Climate Other Blinds Lights Creating a new scheduled scenario „ Press the desired function to open the specific menu. "Creating new scenarios"...
  • Page 40 The following characteristics apply only to the conditions in the ALARM category. The AND/OR function determines whether a number off conditions must be met SIMULTANEOUSLY or if only ONE Key 2 Pass new key of the selected conditions need to be satisfied for the scenario to be activated.
  • Page 41 Edit a key Setup-Key-Advanced functions-Edit „ Press the icon to modify the scenarios associated with User 1 the selected key. User 2 • 2 scenarios may be selected: one IN and one OUT. • Only INSTANT scenarios can be selected! User 3 User 4 „...
  • Page 42 PROTECTION Port Setup-Protection Setup-Audio broadcast-Port From this menu you can manage the system passwords and security parameters. „ Enter the port of the desired audio broadcast server, then confirm. User password Setup-Protection-User password 9000 The USER password (default 111111) is required when you are attempting to access the change User password menu and every time you attempt to access one of the menus for which access has been limited.
  • Page 43 Update configurations indirizzo@comelit.it Setup-Advanced-Update configurations Function not available if Icona Manager is connected to the home automation bus via Comelit Hub 20003150. The function updates all the home automation settings of the system, loading the current settings in the micro SD configured using SimpleProg.
  • Page 44 Scenario 3 Setup-Advanced-Disable Vedo alarm / Enable Vedo alarm Scenario 4 Function not available if Icona Manager is connected to the home automation bus via Comelit Hub 20003150. This function allows you to disable or enable the alarm function of the Vedo control panel and all the characteristics associated with it in the system.
  • Page 45 Icona Manager ViP address should be the same as the Comelit Numero di trasmissioni Hub. Icona Manager should be set as slave, as the master device will be the Comelit Hub. Tempo di polling „ Confirm the operation in order to proceed.
  • Page 46 CAMERAS ACTUATORS Camera 1 Actuator 1 Camera 2 Actuator 2 Camera 3 Actuator 3 Camera 4 Actuator 4 „ Press on the name of the camera, then confirm the operation to „ Press the icon to add a new element. start playback of the camera images.
  • Page 47 Set ringtone repetition Allows you to switch from RTSP mode to ViP See paragraph "CONFIGURE NAME" on page 46 Setup-Advanced-Door entry monitors-Set tone repetition Configure RTSP address This function allows you to set the number times the tone is repeated Configure RTSP username for each of the applicable events.
  • Page 48 • WAITING TIME This is the time interval (in seconds) between the arrival of a call and its diversion (in the case of no reply) to another ViP device. Adjust by pressing "+" and "-". Configure ViP address The waiting time value only applies when the ACTIVATE TIMED DIVERT function is enabled (see below).
  • Page 49 „ Enable/disable communication with Comelit Hub „ Press the icon to enable the function. When enabled, Icona Manager connects to the Comelit Hub using the set parameters. When a connection has been established, you will be directed to the Homepage.
  • Page 50 C E R T I F I E D M A N A G E M E N T S Y S T E M S w w w . c o m e l i t g r o u p . c o m Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy...