Biotech Sequence Precision Series Instruction Manual

96/384 benchtop pipettor

Advertisement

Quick Links

PRECISION SERIES PIPETTOR
Accelerate Liquid Transfers
96/384 BenchTop Pipettor
Instruction Manual
www.sequencebiotech.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sequence Precision Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Biotech Sequence Precision Series

  • Page 1 PRECISION SERIES PIPETTOR Accelerate Liquid Transfers 96/384 BenchTop Pipettor Instruction Manual www.sequencebiotech.com...
  • Page 2 New 2020! 2-Year warranty • Improved accuracy Improved accuracy Improved accuracy • and precision Free lifetime • electronics updates electronics updates electronics updates Extended menu • features The Precision Series Pipettor is an intuitive multichannel pipettor capable of 96 and 384 well formats. Plate stamping, plate reformatting, mixing, and serial dilute have never been so easy and quick.
  • Page 3: Table Of Contents

    ....................23 SPeCiFiCAtioNS ................23 DeCLArAtioN oF CoNForMitY ..........24 ProGrAMMiNG CoMMANDS AND ACtioNS ....... 25 ProGrAMMiNG eXAMPLeS ............26 SERVICE PLANS ..................29 PLANS A–C ..................29 PLAN D ....................30 PLAN SPeCiFiCS ................31 Sequence BioTech, MANUAL 54652...
  • Page 4: Two-Year Warranty

    LIMITED TwO-YEAR PRODUCT wARRANTY this Sequence Biotech, LLC instrument is warranted to be free of defects in materials and workmanship for a period of tWo (2) YeArS from the date of delivery. At its discretion, Sequence BioTech’s manufacturer will repair or replace all defective components during this warranty period.
  • Page 5 Sequence Biotech technical Support at (603)769-0963 or email service@sequencebiotech.com. An authorized service center will reply with a non-binding good faith estimate and a shipping address.
  • Page 6: Safeguards

    Do not attempt to modify any part of the Precision Series Pipettor. if you experience problems with or have questions about your Precision Series Pipettor, contact technical Support at Sequence Biotech at (603)769-0963 or email service@sequencebiotech.com. DANGER •...
  • Page 7: General Information

    Prior to operation, carefully remove instrument and accessories from the shipping container and inspect for damaged or missing items. if any parts are found to be damaged or missing, contact Sequence Biotech technical Support at (603)769-0963 or email service@sequencebiotech.com. Included instrument and accessories:...
  • Page 8: Product Overview

    General Information cont. Product overview the Precision Series Pipettor is a highly precise and accurate, 96/384 well pipettor designed to conveniently process an entire microplate on a laboratory bench top. Supplied with a high performing electric motor and circuit unit, the Precision Series Pipettor ensures precise control in aspirating and dispensing volumes with the touch of a button.
  • Page 9: Parts Of The Pipettor

    Parts of the Pipettor Description Function Control Knob rotate clockwise and counter BMS-54000-itemized manual clockwise to select values Control Panel Contains the keypad and display screen electronics enclosure enclosure houses the 24 VDC electronic components Chassis Assembly Couples the electromechanical linear actuator to Head Assembly Locking thumb Screw Use to lock Head Assembly in low position...
  • Page 10: Recommended Pipette Tips

    General Information cont. recommended Pipette tips SORENSON BIOSCIENCE BRAND the Precision Series Pipettor has been designed for use with Sorenson OneTouch pipette tips. A variety of Sorenson pipette tips create a leak-proof seal and requiring less force to insert than standard tips, making them ideal for sealing 96 tips at once while achieving optimal performance.
  • Page 11: Set Up And Installation

    “home” itself. the instrument is now ready for use. Unlock Unlock Screw Power Cord Vertical Horizontal on to Pipettor Motion Motion and Power Up Sequence BioTech,...
  • Page 12: Adjusting Pipettor Head Assembly

    Set-Up and Installation cont. Adjusting Pipettor Head Assembly The Precision Series Pipettor Head Assembly is easily positioned vertically and horizontally by adjusting the Thumb Screws and sliding the Levered Handle. • Vertical Height Adjustment Set the height that stops the Head Assembly when lowered with the Levered Handle by adjusting the two Height Adjustment Posts located under the Chassis Assembly.
  • Page 13: Adjusting Aspiration And Dispensing Speeds

    Control Wheel to “Motor Speed,” and then select ENTER. • rotate the Control Wheel to select one of the three speeds (“Fast,” “Medium,” or “Slow”), then select ENTER to activate the selected speed. PRECISION SERIES Pipettor Control Panel Sequence BioTech,...
  • Page 14: Adjusting Tip Rack Holder

    Set-Up and Installation cont. Adjusting tip rack Holder To place and pick up tips follow these instructions and refer to the indicated diagram below. Note the cautionary guideline below to avoid personal injury. Slide a rack of pipette tips into the Tip Rack Holder and push it all the way back (a).
  • Page 15: Use Of 384 Well Microtiter Plates

    Contact Sequence Biotech or visit the website for more information. 384 Well Plate Adaptor Optional 384 Well Plate...
  • Page 16: Basic Operation

    Basic Operation Basic operation Buttons operation Action Powers up instrument and begins a “homing” sequence Stops all motion, anytime. Acts as an emergency shut-off button. ASPIRATE requires user to enter a liquid aspirating volume (uL). turn black Control Wheel to select a value between 5 and 250.
  • Page 17 “Service” Hidden service menu used for calibrating volume and speed. Use only when working with a certified Sequence ,” Biotech technician. For more information, contact Sequence Biotech Products technical Support at 800-767-0665 or email info@sequencebiotech.com. “Program” Use to create and save an individual pipetting program into memory.
  • Page 18: General Pipetting Set-Up

    Basic Operation cont. General Pipetting set-Up To ensure safe and accurate liquid handling, follow these simple instructions to operate the Precision Series Pipettor: GENERAL PIPETTING SETUP • ensure Levered Handle is in the upright vertical position. • Slide tip rack into secure Tip Rack Holder and push completely back.
  • Page 19 Head Assembly to the highest position. This ends the basic pipetting operation. To adjust the aspiration and dispensing speeds on the Precision Series Pipettor, see ADJUSTING ASPIRATION AND DISPENSING SPEEDS. Sequence BioTech,...
  • Page 20: Basic Programming Instructions

    Basic Operation cont. Basic Programming instructions the Precision Series Pipettor is easily programmed. A program containing up to 100 individual steps can be created and saved into the internal flash memory. the program may be stored and retrieved by pressing MENU on the Control Panel, then choosing “Program”...
  • Page 21 BUttoN CAUSeS tHe CUrSor to BLiNK. A BLiNKiNG CUrSor UNDer A CoMMAND iNDiCAteS tHAt A VALUe CAN Be MoDiFieD BY rotAtiNG tHe CoNtroL WHeeL. iF tHe CUrSor iS Not BLiNKiNG, tHeN rotAtiNG tHe CoNtroL WHeeL WiLL SeLeCt AN ADJACeNt eNtrY oN tHe DiSPLAY SCreeN. Sequence BioTech,...
  • Page 22: Maintenance

    Bearing Rail gently with a clean tissue once a month. Periodically check for loose screws and tighten if necessary. Alternatively, contact Sequence BioTech Technical Support at (603)769-0963 or email service@sequencebiotech.com and request regular maintenance service or repair.
  • Page 23: Cleaning And Decontamination

    • Complete the DECONTAMINATION CERTIFICATION FORM (available online or in your Sequence Biotech Portfolio). include a copy of this form when shipping any returned item. if a DECONTAMINATION CERTIFICATION FORM is not attached, and a potential radioactive or biological hazard is detected or suspected by Sequence Biotech, the instrument will not be serviced until proper decontamination and certification are completed.
  • Page 24: Handling And Environmental Conditions

    Handling and Environmental Conditions Handling the Pipettor transporting the Precision Series Pipettor is easy, but simple safety precautions are necessary to stabilize it while moving or shipping. the instrument must be locked to prevent the Head Assembly from shifting weight horizontally or vertically, potentially causing instability.
  • Page 25: Environmental

    APProVeD PACKAGiNG CoNtAiNer to AVoiD DAMAGe WHiCH MAY iNVALiDAte tHe WArrANtY. CoNtAiNerS MAY Be PUrCHASeD For A MiNiMAL CHArGe. For ADDitioNAL SerViCe AND SHiPPiNG iNqUirieS, CoNtACt SeqUeNCe BioteCH ProDUCtS At (603)769-0963 or eMAiL SERVICE@SEqUENCEBIOTECH.COM. WArninG: it iS A VioLAtioN oF FeDerAL LAW to trANSPort BioLoGiCALLY HAzArDoUS or rADioACtiVe MAteriALS WitHoUt ProPer PACKAGiNG, LABeLiNG, AND APProPriAte WArNiNGS.
  • Page 26: Appendix

    Appendix Parameter specifications overall Dimensions 16.5” (H) x 18.0” (L) x 10.0” (W) 420mm (H) x 458mm (L) x 254mm (W) Mains Power Supply 100–240 V 47–63 Hz 1.4 A Max input voltage 24 VDC 2.7 A 65 watts operating Conditions, indoor 50–102 F 10–40 C 85% rH non-condensing...
  • Page 27: Declaration Of Conformity

    DecLArAtion oF conForMity Ce, UL & CSA Standards Sequence BioTech, LLC 614 Nashua Street, Unit 223 Milford NH 03055-4917 We declare that the product, Precision series PiPettor is in conformity with: EU Directives: 89/336/eeC electromagnetic Compatibility Directive, amended by 92/31/eeC & 93/68/eeC...
  • Page 28: Programming Commands And Actions

    Appendix cont. Programming commands and Actions there are three upper level commands: “Run,” “Delete,” and “Edit.” For further details on using these basic commands. A program containing up to 100 individual lines (numbered from 0 to 99) can be saved into the internal flash memory. each line consists of one command and up to two parameters.
  • Page 29: Programming Examples

    (Note: the cursor begins to blink when activated). Now rotate the Control Wheel to scroll until “Cls” appears. Press ENTER to select that command. the first line of programming is now complete and saved into memory. Sequence BioTech,...
  • Page 30 Appendix cont. Programming examples | cont. SIMPLE PROGRAMMING EXAMPLE | CONT. • the second line of the program reads, “1 Print Line1 enter to continue”. this line displays a predefined string of text. to program, rotate the Control Wheel counterclockwise to scroll back to line 0, then press eNter to activate that line.
  • Page 31 4 Wait 14 Cls 5 Print Line1 “Aspirate” 15 Print Line1 “Done” 6 Asp 15 16 Print Line2 “Enter to continue” 7 Cls 17 Wait 8 Print Line1 “Prepare to Dispense” 18 End 9 Print Line2 “Enter to continue” Sequence BioTech,...
  • Page 32: Service Plans Plans A-C

    96 Channel Precision Series Pipettors. Under our Performance Service Plans, manufacturer trained technicians will inspect, repair and calibrate your 96 Channel Sequence Precision Series Pipettor, and provide repair notes and “as left” certification. every calibration is documented and follows standard laboratory quality control traceability guidelines.
  • Page 33: Plan D

    Assembly, and a bushing and rail surface lubrication, to be performed at any time during the year designated by customer. For refurbishment, our trained service technician will: remove the pipetting head. Ultrasonically clean all metal parts in the Head Assembly. replace 96 piston seals using oeM parts.
  • Page 34: Plan Specifics

    (603)769-0963 (603)732-0327 ARRANGEMENTS Call or email Sequence Biotech at service@sequencebiotech.com or your sales representative, to schedule warranty work or Service Plan service arrangements. We offer a loaner instrument program to supply you with an instrument while your instrument is being serviced.
  • Page 35 Sequence BioTech o ers four unique Service Plans. Choose the Plan to best fit your needs. Contact sales for more information at info@sequencebiotech.com.
  • Page 36 614 Nashua Street, Unit 223 Milford NH 03055-4917 (603)769-0963 (603)732-0327 www.sequencebiotech.com...
  • Page 37 Important Documents...

Table of Contents