IKEA TILLAGAD Installation Instructions Manual page 14

Front control electric ranges
Table of Contents

Advertisement

Available languages

Available languages

4. Attach terminal lugs to line 1 (black), neutral (white), and line
2 (red) wires. Loosen (do not remove) the setscrew on the
front of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten setscrew to torque
as shown in the following Bare Wire Torque Specifications
chart.
C
D
A. Terminal lug
B. Setscrew
C. Line 2 (red) wire
D. Neutral (white) wire
E. Line 1 (black) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
Wire Awg
8 gauge copper
6 gauge aluminum
14
A
B
E
Torque
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
5. Use a hex or Phillips screwdriver to connect the bare (green)
ground wire to the range with the ground-link screw and
ground-link section. The ground wire must be attached
over the ground-link section and must not contact any
other terminal.
6. Use ³⁄
" (1.0 cm) nut driver to connect the neutral (white) wire
8
to the center terminal block post with one of the 10-32
hex nuts.
A
B
C
A. 10–32 hex nut
B. Line 2 (red) wire
C. Bare (green) ground wire
D. Ground-link screw
7. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Firmly tighten hex nuts.
IMPORTANT: Verify the tightness of the hex nuts.
9. Replace lower access cover.
G
F
D
E
E. Neutral (white) wire
F. Line 1 (black) wire
G. Terminal lug

Hide quick links:

Advertisement

Table of Contents
loading