11.7
Factory conditions for each model are as follows:
737-5
5-LPM output flow @ 80-psig input pressure
737-10
10-LPM output flow @ 80-psig input pressure
11.8
Any output flow greater than the stated maximum output flow for any particular
model pure air generator produces air with purity worse than specifications.
Figures 19 and 20 are nomographs which indicate output flow versus rotameter
reading at STP.
11.9
The operator must realize that once other equipment is connected to the pure
air generator and output flow is controlled at the other equipment, the rotameter
will then be pressurized and will indicate less flow than is actually being
delivered. See Section 4.6.