1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS P210WLP Series Air Dryer! We here at Altec AIR are very proud of our products, and we are committed to providing you with the best value and service possible.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 3. Table of Contents 8.11 Connecting to Common Alarm 1. Welcome & Congratulations ....... 3 Terminals ............. 42 8.12 Connecting via Web Browser ....43 2. Introduction ..........3 8.13 Using the Status Screen ....... 45 8.14 Using the Setup Screen ......
Page 5
13.16 Compressor Excessive AMP Draw ..83 11.3 Accessories for Your Dryer ....74 13.17 High Compressor Last Run Time 11.4 Ordering Parts from Altec AIR .... 74 Alarm ............84 13.18 Can’t Create a High Compressor Last 12. Service & Repair........75 Run Time Alarm ..........
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 4. Safety & Warning Information This section contains general information about safety and warning points to consider and adhere to during installation, operation, and maintenance of your Air Dryer. PLEASE READ THIS SECTION BEFORE PERFORMING ANY OPERATION OR PROCEDURE ON YOUR AIR DRYER.
Page 7
Dryer section will ensure optimal performance over the lifecycle of your Air Dryer. IMPORTANT! Performing procedures not described in this User’s Guide or installing components not supplied by Altec AIR is NOT RECOMMENDED AND MAY VOID THE WARRANTY. P017455 – Rev. C Page 7 of 91...
5. Overview & Specifications 5.1 Product Description The P210WLP Series Air Dryers from Altec AIR are designed to intake wet ambient air and remove the moisture for delivery to applications requiring a constant, on- demand source of dry, pressurized air. This process is fully automatic and will remain consistent with minimal required periodic maintenance.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 5.5 Dryer Function Overview Component Description Inlet Muffler Minimizes compressor intake noise Compressor Compresses air drawn in by the inlet muffler Coalescing Filter Removes liquid water droplets from the airstream prior to the heatless dryer...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6. Installing Your Dryer 6.1 Safety & Warning Information WARNING! Internal surfaces may be hot. Use care when coming into contact with internal components as there is a potential for some of these components to become hot when in operation or standby.
Altec AIR, LLC IMPORTANT! Performing procedures not described in this User’s Guide or installing components not supplied by Altec AIR is NOT RECOMMENDED AND MAY VOID THE WARRANTY. 6.2 Before You Begin 6.2.1 Carefully inspect the unit, including the shipping box as well as the air Dryer, for ANY DAMAGE CAUSED BY SHIPPING.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6.3 Included Contents (1) P210WLP Series Air Dryer (1) 120 VAC Power Cord (P210WLP models) (1) 220 VAC Power Cord (P212WLP models) (4) Connector, Male 1/4 MPT Swivel Elbow (1) Precision Bleed Orifice Fitting...
Page 14
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6.5.3 Check for loose parts, hoses, or wiring. NOTE: If ANY SHIPPING DAMAGE is detected, file a claim with the shipping company prior to continuing the installation procedures. 6.5.4 Remove the wooden shipping block...
Page 15
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6.5.7 For RACK MOUNT installations (See section 7. for wall mount installations): 6.5.7.1 Extend the drawer slide brackets and separate into two components by pressing down on the black lever and pulling apart.
Page 16
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6.5.7.3 Install the larger of the two slide components on the inside walls of the provided U-shaped mounting bracket by inserting two of the supplied 10-32 x 3/8” screws on each side. Use Loctite to secure the screws.
Page 17
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6.5.7.5 Install the U-shaped bracket assembly into the server rack by bolting the two mounting ear brackets to the rails of the rack. Refer to the manufacturer of the server rack to determine the hardware necessary for component installation.
Page 18
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6.5.8 For WALL MOUNT installations (See section 7. for rack mount installations): 6.5.8.1 Each P210WLP Series dryer is shipped with a standard rack mount installation kit. Section 7. outlines the general installation process for wall mounting a P210WLP Series dryer.
Page 19
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6.5.9 Verify that the Dryer is powered OFF. 6.5.10 Plug AC Power Cord to Dryer. 6.5.11 Wire or plug the power cord into: • 110 - 125 VAC power outlet for the P210WLP model •...
Page 20
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6.5.13 Set the System Pressure: With Compressor running: 6.5.13.1 Pull the Capacity Control Valve knob out. 6.5.13.2 Turn the knob until the reading on the pressure gauge is 50 PSI. 6.5.13.3 Push the knob in to lock.
Page 21
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC NOTE: Save this fitting for use in low flow applications. It is recommended that the dryer operates with a duty cycle of 10% or greater. 6.5.17 Connect a 3/8” air supply line to the Outlet Port.
Page 22
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 6.5.19.2 Tighten the retaining nut to lock the knob in place. 6.5.20 Check for air leaks: NOTE: This is a general procedure that can be applied to any fitting or hose that has air pressure in it.
No alarms are present on the Display Panel. 7. Registering Your Dryer Please take a moment to register your PUREGAS P210WLP Series Air Dryer. Registering is necessary to activate the Limited Warranty on your product. Once you register, you are eligible to receive free technical support, as well as updates concerning your Altec AIR products.
IMPORTANT! Performing procedures not described in this User’s Guide or installing components not supplied by Altec AIR is NOT RECOMMENDED AND MAY VOID THE WARRANTY. P017455 – Rev. C Page 24 of 91...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.2 Connecting Air Supply Lines to the Dryer 8.2.1 Connect a 3/8” air supply line to the Outlet Port. NOTE: For all dryers with minimal flow, install the Precision Bleed Orifice fitting to maintain a constant flow of air.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.3.3 Pull the ring handle on the air tank until all the air pressure is released. 8.3.4 Close Top Panel 8.4 Powering the Dryer ON & OFF CAUTION! Incoming power to Dryer must be: •...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.5 Using the Front Panel Display CAUTION! The Display Screen is covered by a clear protective layer that guards against Electrostatic Discharge (ESD). DO NOT REMOVE THIS LAYER. 8.5.1 ALARM LED – Indicates an alarm is present.
Page 28
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.5.5.1 Outlet Screen OUTLET – Outlet Pressure regulated by the Outlet Pressure Regulator TANK –Tank pressure- operates between 20–50 PSI (137.9 – 344.7 KPa). HUMIDITY – Humidity level of the system.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.6 Identifying Dryer Alarms 8.6.1 High Outlet Pressure Alarm - Occurs when the Outlet Pressure (OUTLET) rises above the alarm set point for more than one (1) minute. See section 13.5 for troubleshooting information.
Page 30
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.6.4 High Cabinet Temperature Alarm - Occurs when the temperature in the cabinet rises above 120° F (49° C) for more than ten (10) seconds. If this alarm is present for one (1) minute or more, the Air Dryer will go into SHUTDOWN mode to prevent damage to the unit.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC See section 13.11 for troubleshooting information. 8.7 Adjusting & Resetting Dryer Set Points Dryer Set Points are simply limits programmed for a specific reading. Once this limit is reached (or exceeded) this results in an alarm for that reading. Each of these set points is factory programmed with a default value based on typical usage of the air Dryer.
Page 32
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC o Set High Humidity Threshold o Set High Duty Cycle Threshold o Set Compressor Last Run ❖ Network Setup – Requires System Keyword to Access o Set IP Address o Set Subnet Mask...
Page 33
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.7.2.7 Press the Left () Arrow Button to escape to the system setup menu screen 8.7.3 Reset Compressor Total Hours – 8.7.3.1 Compressor total hours is the number of compressor runtime hours since startup or the last time the compressor time counter was reset.
Page 34
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.7.4.2 From the system setup menu screen, press the Up () & Down () Arrow Buttons to navigate between the system setup options to locate “RESET TO FACTORY DEFAULT VALUES” 8.7.4.3 Press the Enter (●) button to enter the change value screen 8.7.4.4 Press the Right () &...
Page 35
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.7.5.6 Press the Right () & Left () Arrow Buttons to toggle between YES / NO. If YES is selected the unit will be reset to factory default values. If NO is selected the unit will not be reset to factory values, and all previous setpoints will be retained 8.7.5.7 Press the Left () Arrow Button to escape to the system setup menu...
Page 36
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC o High Outlet – Alarm threshold for high outlet pressure o Low Outlet – Alarm threshold for low outlet pressure o High Humidity – Alarm threshold for high outlet humidity o High Duty Cycle –...
Page 37
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.7.7.5 Press the Up () & Down () Arrow Buttons to change the value of the selected digit. Press the Right () & Left () Arrow Buttons to navigate to additional digits to change 8.7.7.6 Press the Enter (●) Button when the value is as desired.
Page 38
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC value. If NO is selected the IP address will not be set to the new value, and the previous IP address will be retained 8.7.8.7 Press the Left () Arrow Button to escape to the Network Setup menu screen 8.7.9 Set Subnet Mask –...
Page 39
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.7.10.2 Press the Enter (●) button to enter the change value screen 8.7.10.3 Press the Right () & Left () Arrow Buttons to move the underscore beneath the digit to change 8.7.10.4 Press the Up () &...
Page 40
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.7.11.5 Press the Enter (●) button when the value is as desired 8.7.11.6 Press the Right () & Left () Arrow Buttons to toggle between YES / NO. If YES is selected the Trap Server will be set to the new value.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.7.12.8 Press the Left () Arrow Button to escape to the system setup menu screen 8.8 Open Panel 8.8.1 Open panel latches and remove the top panel. 8.9 Setting the System Pressure With Compressor running: 8.9.1 Open Panel (see section 8.8 ).
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.10.2 Turn knob until Outlet Pressure (OUTP) reading is at the desired setting. 8.10.3 Tighten the retaining nut to lock value in place. 8.11 Connecting to Common Alarm Terminals 8.11.1 Wire the Alarm Harness to monitoring device using the table below for...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.12 Connecting via Web Browser If the Air Dryer IS connected to an IP network: • The Air Dryer must be configured with a valid IP Address, Subnet Mask, and Gateway Address for the network.
Page 44
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC The Web Browser connection offers five (5) screens to the user: • Status Screen - Displays the readings and alarms monitored in the P210WLP Series Air Dryer. Provides remote ALARM RESET.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.13 Using the Status Screen Displays the readings and alarms monitored in the P210WLP Series Air Dryer. Provides remote ALARM RESET. • Readings are displayed in BLACK unless an alarm is present.
Page 46
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC • Alarm Status will display Alarm if any alarms are present. • Keyword validation is required for ALARM RESET and RESET TOTAL RUN TIME. 8.13.1 Resetting an Alarm 8.13.1.1 Click on the ALARM RESET Button to remotely reset Air Dryer alarms displayed on Status Screen.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.13.2.3 Click on SUBMIT Button when done. 8.14 Using the Setup Screen All configuration of Set Points, Setups, and Keyword can be made in this screen. NOTE: Reference Appendix section 14.2 for Limits, Defaults, and Formats.
Page 48
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.14.1 Changing a threshold or Setup value: 8.14.1.1 Click on the value to change. 8.14.1.2 Type in the new value. 8.14.1.3 Click the ENTER Button when done. 8.14.1.4 Enter Keyword (default is 123456) 8.14.1.5 Click on SUBMIT Button when done.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 8.14.2.5 Click on SUBMIT Button to confirm. This will lock in the new setting value. 8.15 Using the Event Screen Displays all events such as alarms, changes made, and alarm resets registered by the P210WLP Series Air Dryers.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC • Click on the column headings to sort data according to that column. • Click the Arrow Buttons to navigate through all the event log pages. 8.17 Using the Firmware Screen Displays the current firmware version and date of the P210WLP Series Air Dryers.
Page 51
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC • The BROWSE Button allows you to locate the new firmware file. • The ACCEPT Button is used to change values. • Keyword validation is required to update firmware. 8.17.1 Updating the Firmware: 8.17.1.1 Click on...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC .bin file. Press the OK Button. 8.17.1.3 Click the ACCEPT Button when done 8.17.1.4 Enter Keyword (default is 123456) 8.17.1.5 Click on SUBMIT Button when done. This will lock in the new firmware version.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9. Testing Your Dryer 9.1 Safety & Warning Information WARNING! Extreme care should be exercised to avoid contact with live electrical circuits. Many procedures performed during installation, operation, testing, and maintenance of this Air Dryer require the equipment to be running, creating a situation for potential electrical shock.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9.2 Measuring Compressor Amp Draw WARNING! Internal surfaces may be hot. Use care when coming into contact with internal components as there is a potential for some these components to become hot when in operation or standby.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9.3 Measuring Compressor Voltage WARNING! Extreme care should be exercised to avoid contact with live electrical circuits. It is highly recommended that you remove all jewelry before performing any procedures. 9.3.1 Open Panel (see section 8.8 ).
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC With the Compressor NOT running: 9.3.5 Use a Voltmeter to measure across the board terminals where wires #6 and #7 are connected. The voltage should measure 0 VAC (10%) 9.3.6 Replace the clear plastic terminal block cover.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9.4.3 Use a Voltmeter to measure across the board terminals where wires #4 and #5 are connected. The voltage should measure 110 - 125 VAC for the P210WLP or 208 - 253 VAC for the P212WLP.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC • Place your hand behind the purge port to feel for purging air. Air should be steadily purging from the port, and a burst of air should be felt every 60 seconds as the dryer cycles between towers.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC If the voltage does not measure approximately the same as the incoming system voltage the Cycle Timer could be defective. See sections 11.2 for troubleshooting information. 9.7 Testing Air Dryer Fan NOTE: To test the fan, the cabinet temperature must be above 90...
Page 60
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC With Compressor running: 9.8.2 Verify the compressor shuts down when the tank pressure (TANK) reaches 50 PSI (344.7 KPA). If the tank pressure (TANK) fails to reach 50 PSI (344.7 KPA), see section 13.15 for troubleshooting information.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9.9 Testing High Compressor Last Run Time Alarm CAUTION: Be careful when removing Air hose. System is pressurized. NOTE: For this test, allow the Display Screen to cycle through the information screens.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9.10 Testing Humidity Alarm and System Shutdown CAUTION: Be careful when removing Air hose. System is pressurized. 9.10.1 Power the air Dryer OFF. 9.10.2 Depressurize air Dryer (see section 8.3.3) 9.10.3 Disconnect the humidity...
Page 63
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9.10.6 Power the air Dryer ON. Allow the Humidity reading to rise over 10.0%. 9.10.7 After one (1) minute, verify that a Humidity Alarm appears, and the Dryer goes into SHUTDOWN mode.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9.11 Testing High Outlet Pressure Alarm 9.11.1 Make a note of the current Outlet Pressure (OUTP) reading. 9.11.2 Loosen the retaining nut on the outlet pressure regulator. 9.11.3 Turn knob clockwise...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9.11.6 Press the RESET Button to clear the alarm. If you are unable to create a High Outlet Pressure Alarm as described, see section 13.6 for troubleshooting information. 9.12 Testing Low Outlet Pressure Alarm 9.12.1 Make a note of the current...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 9.12.4 Turn Outlet Pressure Regulator knob clockwise until Outlet Pressure (OUTP) reading rises to the reading recorded in step 9.12.1 9.12.5 Tighten the retaining nut to lock the setting in place.
10. Maintaining Your Dryer In order to ensure that your P210WLP Series Air Dryer continues to operate efficiently and reliably, Altec AIR recommends performing preventative maintenance procedures at the specified six month and annual intervals. In the event of a high duty cycle application, it may be necessary to perform preventative maintenance at more frequent intervals, which will be indicated by a compressor total hour alarm.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC It is also recommended that you print out the included Six Month Maintenance (section 10.2 ) and Annual Maintenance (section 10.3 ) log sheets and record all completed maintenance for historical tracking and reference purposes.
Page 69
Your Dryer section will ensure optimal performance over the lifecycle of your Air Dryer. IMPORTANT! Performing procedures not described in this User’s Guide or installing components not supplied by Altec AIR is NOT RECOMMENDED AND MAY VOID THE WARRANTY. IMPORTANT! After performing any maintenance, always soap test pressure fittings to check for air leaks.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 10.2 Six Month Maintenance MODEL: LOCATION NAME: SERIAL NUMBER: ADDRESS: DATE INSTALLED: Maintenance Interval (Months) Procedure Section Measure & Record Compressor Amp Draw Measure & Record Incoming Voltage (must be 110 - 125 VAC for P210WLP models and must be 208 - 253 VAC for P212WLP models) Test High &...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 10.3 Annual Maintenance MODEL: LOCATION NAME: SERIAL NUMBER: ADDRESS: DATE INSTALLED: Note: In the event of a high duty cycle application, it may be necessary to perform preventative maintenance at more frequent intervals, which will be indicated by a compressor total hour alarm.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 11. Replacement Parts & Accessories 11.1 Dryer Parts Recommend Description Part Number Quantity Spare Precision Bleed Orifice P013349 (1) Heatless Dryer Assembly See section 11.2 for detail P013720 (1)
User’s Guide and will not be covered. Please refer to the information included with the specific replacement part for this instruction. Once you have identified your required parts and accessories, contact the Altec AIR Inside Sales / Parts Orders department to order: (800) 521-5351 (option 2) Fax –...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 12. Service & Repair Only Altec AIR can offer factory direct rebuilds backed by a 6 month factory warranty. • 2 week turnaround time • Estimates available upon request • Minimum service charge fee applies 12.1 Services Offered...
PLEASE READ THIS SECTION FIRST. It is important that you use the following sections in order to diagnose and attempt to fix the problem with your Air Dryer before placing a call to Altec AIR Technical Support. This troubleshooting guide is intended to simplify the isolation of problems, present possible causes, provide test procedures for verification, and suggest corrective actions to restore the air Dryer back to normal operation.
DC voltage. This will render the Humidity Sensor defective. IMPORTANT! Performing procedures not described in this User’s Guide or installing components not supplied by Altec AIR is NOT RECOMMENDED AND MAY VOID THE WARRANTY. 13.3 Air Dryer Won’t Power ON...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 13.4 Display Screen Not Functioning Possible Cause Check Corrective Action Dryer experienced a Power the air Dryer power surge OFF for 15+ seconds. Power the air Dryer Ribbon cable Verify ribbon cable...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 13.9 High Humidity CAUTION! Do not test the Humidity Sensor with an ohm meter or apply any DC voltage. This will render the Humidity Sensor defective. Possible Cause Check Corrective Action...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 13.10 Can’t Create a High Humidity Alarm / Shutdown These troubleshooting steps assume that the Humidity Element is removed from the Humidity Block during the Testing Humidity Alarm and System Shutdown (section 9.10 ) procedures.
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC High Ambient Verify temperature of Lower the ambient Temperature Dryer operating temperature of the location. Recommended Dryer’s operating ambient temperature is location 40°-85°F. 13.13 Inconsistent Heatless Dryer Cycling Possible Cause Check...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 13.15 Compressor Won’t Build Pressure Possible Cause Check Corrective Action Low System Pressure Verify System Pressure Adjust System Pressure (section 8.9 ) to 50 PSI, ± 2 PSI. (section 8.9 )
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 13.17 High Compressor Last Run Time Alarm Possible Cause Check Corrective Action Low System Pressure Verify System Pressure Adjust System Pressure (section 8.9 ) to 50 PSI, ± 2 PSI. (section 8.9 )
11.1 ) 13.20 Contacting Altec AIR Technical Support Please read the Before You Call Altec AIR section (13.1 ) Once you have exhausted all of the potential problems and solutions covered in the Troubleshooting Your Dryer section, and you still require further assistance to correct...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 14.2 Set Point Limits and Defaults 14.2.1 System Adjustments Minimum Maximum Default Unit of Description Value Value Value Measurement System Pressure Outlet Pressure 0.30 (2.1) 7.5 (51.7) PSI (KPA) Alarm Delay 14.2.2 Alarm Set Points...
P210WLP Series Air Dryer User’s Guide Altec AIR, LLC 14.3 SNMP Parameters Device Configuration Information Device ID Alphanumeric (Defined by Customer) Device Model Alphanumeric (Factory Preset) Device Firmware Version Numeric (Factory Preset) Current Date/Time Numeric (mm/dd/yy hh:mm) IP Address Numeric (xxx.xxx.xxx.xxx) Subnet Mask Numeric (xxx.xxx.xxx.xxx)
Broomfield, Colorado. Freight charges are the responsibility of the user. This warranty shall not apply to any Altec AIR product which shall have been repaired or altered in any way by anyone other than Altec AIR or authorized personnel so as to affect, in our judgment, its proper functioning or reliability, neither will it apply to any product which has been subject to misuse, negligence, or accident.
Need help?
Do you have a question about the Puregas P210WLP Series and is the answer not in the manual?
Questions and answers