Infinity PS Series Service Manual page 4

Hide thumbs Also See for PS Series:
Table of Contents

Advertisement

PS series PS28 subwoofer
Parameter
Turn-off Transient
Efficiency
Stand-by Input Power
Power Cons.@rated power
Protection
Short Circuit Protection
Thermal Protection
DC Offset Protection
Line Fuse Rating
120 VAC
230 VAC
Specification
Unit
QA Test Limits
100
50
mV-peak
12
Watts
15
195
Watts
210
Functional
YES
--
65 deg. C
--
Functional
YES
--
Functional
2.5
Amps
1.25
Amps
Conditions
@ Speaker Outputs
@ nom. line voltage
@ nom. line voltage
Direct short at output
@1/8 max unclipped Power
DC present at Speaker Out leads
Type-T or Slo Blo
Type-T, Low breaking capacity
3
Notes
AC Line cycled from ON to OFF
Maximum allowable input power under
nominal Input voltage and frequency, HOT
or COLD operation.
100 Watts @ 4 Ohms nominal line voltage
Temperature rise should not exceed 35K
rise
Relay or crowbar (for driver/fire protection)
External fuse with UL/SEMKO rated holder

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps28

Table of Contents