Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Grundfos Manuals
Amplifier
Conex DIA-2
Installation and operating instructions manual
Instrument Settings - Grundfos Conex DIA-2 Installation And Operating Instructions Manual
Instrument amplifier and controller
Hide thumbs
Also See for Conex DIA-2
:
Installation and operating instructions manual
(612 pages)
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
page
of
56
Go
/
56
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
3. Instrument settings
Setup
Parameter
Chlorine:_
Chlorine dioxide:_
Ozone:_
Peroxide:_
Temp. meas.
Yes:_
No:_
Temp. comp.
Yes:_
No:_
pH compensation
Yes:_
No:_
Measuring ranges
mg/l (ppm)
Current output 1
mA
Measuring cell
Measuring cell type
Cleaning motor
Monitoring on:_
Monitoring off:_
Water sensor
On:_
Off:_
4
Parameter 1
Controller
Setpoint contrl.
Off:_
Limit:_
Interpulse ctrl.:_
Pulse freq. ctrl:_
Cont. controller:_
Limit contact
Downward viol.:_
Upward violation:_
Ctrl. direction
Downward control:_
Upward control:_
Type of control
P:_
PI:_
PID:_
Controller
Proportional Xp
%
Reset time TN
(PI/PID control)
sec.
Deriv. action Tv
(PID control)
sec.
Int.pulse period
(interpulse ctrl.)
sec.
Min. ON time
(interpulse ctrl.)
sec.
Max. frequency
(pulse freq. ctrl)
n/min
Setpoint
(limit contact)
Constant load
%
Max. dosing flow
%
Limit
(limit contact)
Hysteresis
(limit contact)
Alarm
Alarm
On:_
Off:_
Alarm value 1
Switching point
Alarm value 1
Switching direction
Upward violation:_
Downward viol.:_
Alarm value 2
Switching point
Alarm value 2
Switching direction
Upward violation:_
Downward viol.:_
Hysteresis
Alarm delay
sec.
Dos. time monit.
On:_
Off:_
Dos. time monit.
Max. dosing time
min
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
6
7
8
Advertisement
Table of Contents
Related Manuals for Grundfos Conex DIA-2
Measuring Instruments Grundfos Conex DIA-2 Installation And Operating Instructions Manual
Instrument amplifier and controller (612 pages)
Amplifier Grundfos Conex DIA-2Q Installation And Operating Instructions Manual
Instrument amplifier and controller (56 pages)
Related Content for Grundfos Conex DIA-2
Conex DIA-2Q Instrument Settings
Grundfos Conex DIA-2Q
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL