Advertisement

Installation Guide
Contents
Page 2
Page 4
Page 5
Page 10
Page 10
Page 12
Page 14
Page 16
Page 22
Page 23
Page 24
Page 25
Page 26
Page 28
Page 32
POE
Box Contents / Safety Information / Product Introduction
Factory Defaults / Complete Set Up and Installlation
Power Up Functionality ; Re-Set Options
Re-enabling Manual Buttons and Remote Controller
Specifications Table
Troubleshooting
Quick reference tables for Manual Button Control and
Remote Controller guide for PIN Set and Manual Button

Advertisement

Table of Contents
loading

Summary of Contents for RayLED VARIO2 POE Series

  • Page 1: Table Of Contents

    Installation Guide Contents Page 2 Box Contents / Safety Information / Product Introduction Page 4 Installation Guide – Short Guide Page 5 Factory Defaults / Complete Set Up and Installlation Page 10 LED Status Indicators – Feedback System Page 10 Programming Mode and Operating Mode Page 12 VARIO Remote Controller (VRC)
  • Page 2 For Standard and Premium Variants : The illuminator has a photocell for automatic day/night switching and also benefits from RayLED’s interchangeable lens system so that the correct angle of illumination can always be achieved easily. RayLED Tel : +33(0) 4 58 00 15 74...
  • Page 3 External Input, volt free or TTL – orange (TTL +ve) & purple (TTL GND) for illustrative External Output, volt free – yellow & white CAT 5 Cable purposes for PoE RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 4: Installation Guide - Short Guide

    STEP 1: Safety Information (Pg. 2) STEP 2: Physical Installation (Pg. 5) Adjust interchangeable lens if required. Fix to wall, pole or camera unit using U bracket provided or other RayLED bracketry. IMPORTANT: Ensure illuminator is rated to provide required viewing distances and select...
  • Page 5 Step 2 : Physical Installation VARIO2 PoE is delivered as standard with bracket at the bottom of the unit. This can be moved to top of the unit if required. RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 6 Ensure you make a waterproof connection to the RJ45 as shown below. Ensure the connector is waterproof and sealed after the connection is made. To illuminator RJ45-RJ45 connector To PSE RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 7 Wire Gauge (AWG) Orange External Input -Volt free or TTL +ve Purple External Input -Volt free or TTL GND Yellow External Output – Volt free White External Output - Volt free RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 8 Step 4 : Interchangeable Lenses: Changing the Angle Step 2 Step 3 Step 1 Remove Remove / Unscrew Step 4 baseplate Replace diffuser baseplate Replace lens baseplate & tighten RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 9 – See Detailed Section Step 6 : Security (Optional PIN protection) Set PIN (If Required) (Can only be done with the optional VARIO Remote Controller (VRC) – See Detailed Section RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 10: Led Status Indicators- Feedback System

    Operating Mode. However, if you use the manual push buttons at all during this time, the illuminator will automatically enter operating mode 30 minutes after the last button press. RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 11 The only function of the Remote Controller available during Operating Mode is LED Status Indicators Enable/Disable, entering a PIN or disabling manual push buttons (if done at the same time as disabling the remote – see P. 22) RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 12: Vario Remote Controller (Vrc)

    Note : Reset button will not remove a PIN if one is present Note : Unless detailed as part of the functionality, if an invalid or blocked command is attempted, both LEDs will flash RED RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 13 Please see PIN Function Guide (P. 10) for full details on how to use the PIN function. Note : Unless detailed as part of the functionality, if an invalid or blocked command is attempted, both LEDs will flash RED RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 14: Pin Function Guide

    FLASHING GREEN shows that a PIN has been previously set. As you input the four correct characters the number of flashes will reduce and you will be returned to programming mode. RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 15 *Note – If you are trying to access a PIN in Operating Mode, hold the status button down for 4 seconds and both LEDs flash RED, this means there is no PIN present. RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 16: Manual Control Push Buttons

    RHS LED. The buttons are active in both programming mode and operating mode regardless of whether a PIN is present, unless you have previously disabled the manual buttons. RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 17 LEDs will flash Red *Note: – If the status indicator LEDs are disabled and you use the manual buttons the indicator LEDs will still illuminate accordingly RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 18 RHS LED will be stored into the illuminator memory. The settings programmed by the manual push buttons will be retained upon power recycling unless a reset has been performed, in which case the factory defaults will be applied. RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 19 Photocell Level Mode (LHS LED: Solid GREEN) Low sensitivity: RHS LED 1 Flash GREEN Medium Sensitivity: RHS LED 2 Flashes GREEN High Sensitivity: RHS LED 3 Flashes GREEN Disabled photocell: RHS LED Solid RED RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 20 LEDs will go blank for 1 second and then return to the standard indication of either operating mode or programming mode (depending on which mode the illuminator was in previously before selecting manual controls) RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 21 Illuminator will default into Operating Mode 30 minutes after the last button press (e.g. if you press any manual button at 29 minutes – your 30 minute window will start over). RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 22: Disabling Manual Buttons

    Note : This command can only be used within 5 minutes of the illuminator being put into Operating Mode.(If the Manual Buttons are already Disabled, both LEDs will flash RED straight away) RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 23 This is a FULL RESET and will restore factory settings AND remove the PIN if one has been set. Both Indicator LEDs will flash AMBER when completed. RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 24  If no PIN is present you need to re-cycle the power to re-enter programming mode which re-enables the remote  If a PIN is present - You need to enter your PIN - Or do a full Re-set RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 25: Standard Bracketry

    Standard Bracketry : Supplied with the Product (Model Dependant) (Not to scale, dimensions rounded to nearest mm) RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 26 100 x 135 x 66m 75 x 100 x 64mm Dimensions (5”x7”x3”) 4”x5”x2.5”) 3”x4”x2.5”) Cat 5 Cable 2.5m 2.5m 2.5m 2.5m 2.5m 2.5m 2.5m Length For Covert IR940nm Distances please contact RayLED RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 27 2.5m Length Auxillary 2.5m 2.5m 2.5m 2.5m 2.5m 2.5m 2.5m Cable Length For Covert IR940nm Distances please contact RayLED Standards: CE (Covering EMC, Safety, IP rating) IEC/EN 62471 (Photobiological Safety) RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 28  (Note : It is sometimes difficult to see Infra-Red illuminators working in high brightness conditions). • If Premium variant - Ensure telemetry wires are shorted out or valid telemetry input (zero volt or TTL) is applied and correctly wired RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 29 In extreme sunlight conditions, distance between remote and unit may need to be reduced Programming may be disabled. Enter PIN to retrieve control or RESET illuminator using one of the two RESET modes. RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 30 Too wide and there may be insufficient light on scene and light going where it is not needed.  Check Camera model number to RayLED performance specification to ensure required distance is achievable RayLED Tel : +33(0) 4 58 00 15 74...
  • Page 31 Camera make and model • Camera Lens make and model If the RayLED illuminator or remote control is still not delivering the required performance, please contact us for further assistance: RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 32: Disable/ Enable

    If a PIN Enable is present and Remote and you are in Enter Operating Programming Mode you Mode cannot change to Programming Mode – unless you enter your PIN first RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 33 If no buttons are pressed within 2 minutes then the illuminator will automatically default back into the previous mode it was in – programming or operating mode. RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 34 Hand flashing Remote Solid Amber Amber LED Control> - Off go Solid for 4 Amber when seconds the disable remote button is pressed and turn off when in Operating Mode RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 35 – Flashing Programming Button> 4 times Red counts Mode after for 4 Flashing down the PIN deleted. seconds Red / No. of valid Green - characters Green required – Flashing Amber RayLED Tel : +33(0) 4 58 00 15 74 www.rayled.com...
  • Page 36 VA2 POE/16/1.0 RAYLED VIRTUAVIA 2 RUE MARCEL BENOIT 38000 GRENOBLE FRANCE www.RayLED.com Tél: + 33 4 58 00 15 74 Fax: + 33 9 55 70 03 53 www.rayled.com...

Table of Contents