Page 1
PRODUCT USERS: read this manual and the flow control device instruction manual and follow the product user safety instructions (page 10). Manuals are regularly updated. Make sure this manual is available to all users for reference. CURRENT VERSION OF MANUAL AND OTHER LANGUAGES: rpbsafety.com/respirators/z4 The Respiratory Protection Brand ®...
DANGER Indicates a hazardous situation that, if not avoided, will result DANGER in death or serious injury. Read the Instruction Manual. Additional copies of RPB manuals can be found at www.rpbsafety. ® com. CERTIFIED BY: BSI Group The Netherlands B.V., Say Building, John M.
® ® ® ® significantly reduces, but does not completely eliminate, the breathing of contaminates by the respirator wearer. Specific protection depends on the filter selected for use in the RPB ® ® or the RPB PX4 AIR PAPR (see PX5 or the PX4 AIR Instruction Manual).
Page 5
This respirator includes a pair of 18-524 Slimline Earmuffs. The earmuffs are an integral part of the respirator. Please follow the user instructions when fitting the earmuffs to ensure proper wear, fit and protection levels. WARNING The earmuffs must be worn while using the Z4 respirator. ®...
Page 6
PROTECTION PROVIDED AND LIMITATIONS CONTINUED WELDING: This product is tested and certified to EN 175:1997. PPE REGULATION: The Z4 conforms to the PPE Regulation (EU) 2016/425. ® The Declaration of Conformity can be found at rpbsafety.com/resources/ ...
3. AIR SUPPLY maintenance manuals for information PAPR on use and maintenance of these respirators. FIGURE 1.1 The Z4 is not evaluated as a respirator ® for use as a surgical mask. CAUTIONS AND LIMITATIONS POWERED AIR Not for use in atmospheres containing less than 21% ±1% oxygen.
PAPR Instruction ® ® Manual for more details. EMPLOYER RESPONSIBILITIES Your specific responsibilities may vary by location and industry, but in general RPB expects that ® employers will: Follow all applicable standards and regulations for your location, industry, and activity.
Page 9
Train employees in the Z4 ’s use, maintenance, and limitations. ® Appoint a qualified individual who is knowledgable about the RPB per government ® ® regulations where required to provide training: Qualifications of the Respirator Trainer. Anyone providing respirator training shall: a) be knowledgable in the application and use of the respirator(s);...
RPB products you are using. ® MAKE SURE THE SYSTEM IS READY FOR USE Make sure you have a complete system. Verify that you have all required components for the Z4 ® to serve as a complete approved respirator: ...
Page 11
VERIFY THAT YOU HAVE THE APPROPRIATE EQUIPMENT FOR YOUR ACTIVITY Verify that the Z4 provides appropriate protection for your activity. As applicable, check your ® workplace safety program, respiratory protection program, and standards and regulations for your activity or industry. (See PROTECTION PROVIDED AND LIMITATIONS, page 4.) BEFORE DONNING THE Z4 ®...
Page 12
Welding in Confined Spaces Welding in a confined space can present an atmospheric hazard due to the generation of contaminants and displacement of oxygen. Do not use the Z4 in confined spaces if the oxygen ® concentration will be reduced below 21% ±1%.
FIGURE 2.2 Screw the breathing tube (04-837) onto the Optionally, the breathing tube can be threaded air intake on the side of the Z4 ® passed through the loop on the back of the Weld Visor and screw the breathing tube in face seal/cape to keep it centered and out completely without over tightening.
Page 14
® RESPIRATOR SETUP AND CARE CONTINUED IMPACT LENS REPLACEMENT FIGURE 3.1 FIGURE 3.2 To replace the Impact Lens, lift up the Weld Remove the Impact Lens by squeezing the Visor, unlatch the green ADF Retainer from lens to remove it from the tabs on the sides. the Face Shield by pushing the tabs apart and pushing forward.
Page 15
ADF LENS REPLACEMENT AND CLEANING FIGURE 4.1 FIGURE 4.2 Follow steps 3.1 and 3.2 remove the ADF Press the down on the clip at the bottom of Retainer and the Impact Lens. the ADF so that the ADF can slide out. FIGURE 4.4 FIGURE 4.3 Once removed, the ADF can be cleaned...
Page 16
® RESPIRATOR SETUP AND CARE CONTINUED FIGURE 4.6 FIGURE 4.5 Place the cleaned or new ADF Lens into Place the green ADF Retainer back over the the Weld Visor with the solar panel towards Impacts Lens by inserting the bottom guides the bottom and clip it in.
Page 17
The fixed shade lens and frame can be used in place of the ADF for welding and other applications requiring light filtering. Choose an appropriate shade lens depending on the application. Install the lens frame with a lens installed into the Z4 the same way as installing ®...
Page 18
® RESPIRATOR SETUP AND CARE CONTINUED SIDE WINDOW REPLACEMENT FIGURE 6.2 FIGURE 6.1 To replace the side windows, lift up the weld From the inside of the Weld Visor, unclip visor, unlatch the green ADF Retainer from and rotate the side windows to the outside. the Face Shield by pushing the tabs apart and pushing forward.
Page 19
WELD VISOR REPLACEMENT FIGURE 7.1 FIGURE 7.2 Turn the green adjustment knobs counter- When the adjustment knobs are removed, clockwise to loosen until they are able to be the head harness, brackets, and removed. components can be removed. Place the new Weld Visor onto the Face Shield.
Page 20
® RESPIRATOR SETUP AND CARE CONTINUED SAFETY LENS REPLACEMENT FIGURE 8.2 FIGURE 8.1 Lift up the Weld Visor. Using a coin or an Remove the protective film from the inside hex key, twist the green knobs that secure of the lens. Place the lens against the seal the Safety Lens to remove them and then and insert the knobs into the slots and twist remove the lens.
Page 21
HEAD HARNESS ADJUSTMENT FIGURE 9.2 FIGURE 9.1 To adjust the top straps on the head To loosen the top straps, unclip the end tabs harness, push the two straps together to from over the strap. Then pull the straps tighten. apart to the desired notch.
Page 22
Rotate the visor to the desired angle using wearers face, loosen the adjustment knobs, the notches on the right side adjustment without removing them, on the outside of bracket from the inside of the Z4 ® the Weld Visor. FIGURE 10.3...
Page 23
BROW PAD REPLACEMENT, CLEANING AND WELD VISOR CLEANING AND DISINFECTING DISINFECTING FIGURE 11.1 FIGURE 12.1 Place the brow pad onto the inside of the Clean and disinfect the shell of the weld front strap of the head harness. Fold the top visor with a disinfecting wipe or mild house and bottom over and secure the hook and hold cleaner and a soft cloth.
Page 24
® RESPIRATOR SETUP AND CARE CONTINUED FACE SEAL INSTALLATION FIGURE 13.1 FIGURE 13.2 Loosen the left side adjustment knob and Insert the tab on the left side of the face seal attach the two holes in the face seal over band into the slot underneath the air intake.
Page 25
IR/UV filter, it arc. There should be no tension on the ADF protects against hazardous infrared (IR) and Lens caused by the Z4 visor, as it could ® ultraviolet (UV) light. The protection against cause severe damage to the filter.
Page 26
Do not apply paints, solvents, applications and a longer delay with adhesives or self-adhesive labels except as applications using higher currents and instructed by RPB . This product may be ® longer welding intervals. Longer delay can adversely affected by certain chemicals. Do...
Page 27
The marking on the ADF indicates: Use type CR2032 batteries as depicted. 3 / 9-13 RPB 1 / 1 / 1 / 2 / EN379 Carefully remount battery cover. If the automatic welding filter does not darken when the welding arc is ignited, please check battery polarity.
Page 28
® AUTO-DARKENING WELDING PROTECTION FILTER CONT’D TROUBLESHOOTING Shade automatic welding filter does not ADF flickers: darken: Adjust sensitivity Adjust sensitivity Replace batteries Clean sensors and clean or change the Poor vision: impact lens of the helmet shell ...
Page 29
DESCRIPTION OF RPB FILTER FEATURES ® Figure 14.2 Solar Cells Liquid crystal shutter viewing area Photo-sensors (Photo diodes) Shade adjustment Filter housing Sensitivity adjustment functions and settings Opening time delay adjustment IR - Detection Sensitivity Shade Delay Twilight Fast CR2032...
Determine if your company should establish a pre-doffing cleaning program if contaminants on the outside may be dangerous. DONNING YOUR HELMET Once you have completed the set up, you are ready to fit your RPB Respirator. First, put ®...
STORAGE After use, clean the respirator according to your company’s cleaning program or the directions in this manual. Then let it dry, and store the respirator by hanging it up in a clean, dry place, away from the work area. Before storing the respirator for an extended period of time, clean the unit following the cleaning instructions in this instruction manual.
RPB logo and part number), and only in the specified configuration. Using incomplete ® or inappropriate equipment, including the use of counterfeit or non-RPB parts, can result ® in inadequate protection and will void the approval of the entire respirator assembly.
Page 33
FACE SHIELD FIGURE 17.2 Item No. Description Part No. Face Shield 15-811 Safety Lens (10 Pack) 15-878 Safety Lens Bayonet (Pair) 15-832 Air Intake Assembly with Screws 15-851 Front Cape Clip Cover 15-831 ACCESSORIES FIGURE 17.3 Item No. Description Part No. FR Face Seal 15-711 FR Shoulder Cape...
Page 34
® PARTS AND ACCESSORIES CONTINUED HEAD HARNESS AND EARMUFFS FIGURE 17.4 Item No. Description Part No. Head Harness Assembly (Includes 16-530) 15-840 Head Harness Bracket and Adjustment System 15-830 Ratchet Assembly 16-530 Brow Pad 16-526 Quiet-Slim Ear Defenders 18-524 ™...
Page 35
PAPR PARTS AND ACCESSORIES FIGURE 17.5 Item Number Description Part Number PAPR and Belt 03-801-FR-G ® Breathing Tube for PX5 PAPR 04-831 ® Flow Meter PX5 PAPR 03-819 ® PX4 AIR PAPR and Belt 03-901-FR-G ® Breathing Tube for PX4 AIR PAPR 04-837 ®...
Safety is not liable for damage, loss or expense resulting from the failure to give advice ® or information or the giving of incorrect advice or information, whether or not due to RPB ® Safety’s negligence or that of its employees, agents or subcontractors.
Bovendien is het Vision-Link Licht beschikbaar om het werkgebied te verlichten. ™ Platte, ‘in de nek’ oorbeschermers kunnen ook samen met het Z4 Laskap worden gedragen. ® Dit product moet te allen tijde worden geïnspecteerd en onderhouden in overeenstemming met deze gebruiksaanwijzing.
Page 38
RPB Safety, LLC. Neem voor technische ondersteuning contact op met onze Klantenservice: 1-866-494-4599 of e-mail: customerservice@rpbsafety.com...
Page 39
Motoraangedreven Lucht Het RPB Ademhalingstoestel is gekeurd volgens EN 12941:1998 +A1: 2003 +A2: ® ® 2008 TH3, indien correct gemonteerd en gebruikt met alle benodigde onderdelen, inclusief de Ademhalingsslang en het RPB of de RPB PX4 AIR Motoraangedreven ® ®...
Page 40
Dit ademhalingstoestel bevat een paar 18-524 Slimline oorbeschermers. De oorbeschermers zijn een integraal onderdeel van het ademhalingstoestel en moeten worden gedragen tijdens het gebruik van het Z4 ademhalingstoestel. Volg de ® gebruiksaanwijzing bij het passen van de oorkappen om te zorgen voor de juiste pasvorm en bescherming.
Page 41
Vervang nooit onderdelen, pas ze niet aan en laat ze niet weg. Gebruik alleen exacte vervangende onderdelen die door de fabrikant zijn aangegeven. Raadpleeg de gebruiksaanwijzing en/of onderhoudshandleidingen voor informatie over gebruik en onderhoud van deze ademhalingstoestellen. De Z4 is niet geëvalueerd voor gebruik als een chirurgisch masker. ® LUCHTBRON...
Page 42
Train medewerkers in het gebruik, onderhoud en de beperkingen van de Z4 ® Benoem een gekwalificeerd persoon met voldoende kennis over de RPB ®...
Page 43
PAPR heeft gelezen (extra exemplaren beschikbaar op www.rpbsafety.com) en ® getraind bent in het gebruik, het onderhoud en de beperkingen van het ademhalingstoestel door een gekwalificeerd persoon (benoemd door uw werkgever) die kennis heeft van het RPB ® ® Ademhalingstoestel.
Page 44
Raadpleeg Montage en Onderhoud van het Ademhalingstoestel (pagina 46). Zie Donning (pagina 53) voor informatie over de pasvorm. CONTROLEER OF DE UITRUSTING GESCHIKT IS VOOR UW WERKZAAMHEID Controleer of de Z4 de juiste bescherming biedt voor uw werkzaamheid. Controleer, indien van ®...
Page 45
PX4 AIR nooit op hete oppervlakken. Breng geen verf, oplosmiddelen, ® ® kleefstoffen of zelfklevende etiketten aan, tenzij aan de hand van instructies van RPB . Bepaalde ® chemicaliën kunnen schadelijk zijn voor dit product. Zie het gedeelte “Inspectie en Reiniging” voor specifieke reinigingsinstructies.
Page 46
® Eenmaal verwijderd, kan de ADF worden Wanneer het Z4 Ademhalingstoestel wordt ® gereinigd met een zacht doekje met een gebruikt in combinatie met de RPB ® ® mild reinigingsmiddel (of alcohol). of de RPB PX4 AIR PAPR, raadpleeg de ®...
Page 47
VERGROOTGLAS AFBEELDING 6.3 OP PAGINA 18 AFBEELDING 5.1 OP PAGINA 16 Vanaf de buitenkant van de Laskap, roteer Zet de linker beugel van het lasvergrootglas de zijruiten naar binnen, en zorg ervoor dat vast met de meegeleverde schroeven, door ze volledig worden vastgedrukt zonder dat deze stevig aan te draaien zonder ze te er nog licht langs de randen binnenkomt.
Page 48
Steek de schroef in het midden rechterkant van de verstelbeugel aan de van het vizier door het gat in de binnenkant van de Z4 ® gelaatsafdichting,door de voorste clip, en AFBEELDING 10.3 OP PAGINA 22 in het schroefgat in het vizier.
Page 49
In combinatie Er mag geen spanning op de ADF-Lasruit met de permanente passieve IR/UV- worden veroorzaakt door het Z4 -vizier, ® filter beschermt deze tegen gevaarlijk omdat dit ernstige schade aan de lasruit kan infrarood (IR) en ultraviolet (UV) licht.
Page 50
De code op de ADF geeft aan: VERTRAGINGSTIJD: 3 / 9-13 RPB 1 / 1 / 1 / 2 / EN379 De vertragingstijd kan worden aangepast van 0,15 tot 1,0 seconde. Het wordt aanbevolen om een kortere vertraging...
Page 51
aanbevolen lichtgevoeligheidsinstelling zichzelf automatisch uit. Om de automatisch in een standaardsituatie. verduisterende lasruit te reactiveren, moeten Vertragingstijd. Met de schakelaar de zonnecellen kort worden blootgesteld achter het klepje van de batterij, kan de aan daglicht. Als het patroon niet opnieuw vertragingstijd worden ingesteld van kan worden geactiveerd of niet verduistert donker naar licht.
Page 52
® BESCHRIJVING VAN DE MAG (Metaal Actief Gas) TIG (Wolfraam Inert Gas) FUNCTIES VAN DE RPB ® MIG Zware Metalen LASRUIT MIG lichte metalen - Roestvrij, Aluminum AFBEELDING 14.2 OP PAGINA 29 Plasmasnijden Zonnecellen Micro plasmalassen Fotosensoren (Fotodioden) *Verduisteringsniveau 14 valt niet binnen het Behuizing Lasruit bereik van deze ADF.
Page 53
Maak de bovenband vast met de klittenband. AFBEELDING 15.2 OP PAGINA 27 Na de binnenkant van de kap op stof en vuil te controleren, trek de Z4 over de oorbescher- ®...
Page 54
(gemarkeerd met het RPB -logo en onderdeelnummer) en ® alleen in de aangegeven opstelling. Gebruik van onvolledige of ongeschikte uitrusting, waaronder het gebruik van nagemaakte of niet-RPB -onderdelen, kan resulteren in ® onvoldoende bescherming en maakt de keuring van het volledige ademhalingstoestel...
Page 55
ACCESSOIRES AFBEELDING 17.3 OP PAGINA 30 Item Nummer Beschrijving Onderdeel Nummer FR Gelaatsafdichting 15-711 FR Schouder-Cape 15-721 Voorzijde Cape Clip - Vision-Link Montuur 15-839 ™ Vision-Link Licht 16-901 ™ HOOFDBAND EN OORBESCHERMERS AFBEELDING 17.4 OP PAGINA 31 Item Nummer Beschrijving Onderdeel Nummer Hoofdbandenstel (Inclusief 16-530) 15-840...
Page 56
® ® tevredenheid te bepalen of een geclaimd defect onder deze beperkte garantie valt. Als er defect optreedt dat onder de garantie valt, zal RPB naar eigen goeddunken het defecte ® Product (of een onderdeel van het product) repareren of vervangen. Deze ‘reparatie of vervanging’...
Page 60
POWERED AIR RESPIRATOR Polluted air can be the cause of major health issues. How can you improve the quality of the air your employees are breathing? The RPB PX4 AIR is a ® ® powered air purifier that is ergonomic and lightweight, designed to withstand harsh conditions.
Need help?
Do you have a question about the Z4 and is the answer not in the manual?
Questions and answers