Safety Regulations; Ex-Data - Ecom Lite-Ex LED 8 Operating Instructions Manual

Table of Contents

Advertisement

The safety and integrity of the unit may be compromised by,
for example:
- External damage to the housing.
- Exposure to excessive loads.
- Incorrect storage of the unit.
- Damage sustained in transit
- Correct certification is illegible.
- Functioning errors occur
- The permitted limitations are exceeded

4. SAFETY REGULATIONS

The use of the intrinsically safe Lite-Ex LED 8 meets the requirements of
the regulations providing that the user observes and applies the
requirements as laid down in the regulations and that improper and
incorrect use of the unit is avoided.
The device must not be opened within the Ex-hazardous area.
Batteries (see technical data) must only be changed outside the Ex-
hazardous area.
The LED (see technical data) must only be changed outside of the
Ex-hazardous area.

5. EX-DATA

Certificate of Confomity:
Certification
Permitted for Zone 1, Equipment group II, Gas group C hazardous
gases, vapour or mist, Temperature class T4.
Report Job Identification No.:
FM-Certification:
Permitted for Zone 0, Equipment group II, Gas group C,
Temperature class T4.
: TÜV 01 ATEX 1692
:
II 2 G EEx ia IIC T4
3010859
Class I Zone 0 AEx ia IIC T4
I.S. Class I Division 1 Group A-D T4
11