Periodic Message Commands; Avt-84X Field Reflashing; Avt-84 X Re Flash Ing - Avt Provided Application - AVT 84 Series Manual

Multiple interface
Table of Contents

Advertisement

27. ; Define periodic message #03
78 18 03 48 6B 10 41 0D 23
28. ; Enable periodic message #03
73 1A 03 01
29. ; Note that nothing will be transmitted until the group control is set to Type2
30. ; Define periodic message #05
78 18 05 48 6B 10 41 0D 45
31. ; Enable periodic message #05
73 1A 05 01
32. ; Define periodic message #07
78 18 07 48 6B 10 41 0D 67
33. ; Enable periodic message #07
73 1A 07 01
34. ; Set Group1 Type2 interval for a count of $19 (decimal 25)
; the actual interval = 2.4575 sec.
73 1B 01 19
35. ; Enable Group1 for Type2 operations
; At this point all enabled messages in Group1, will begin transmitting in sequence, one
message every 2.4575 seconds.
73 0C 01 02

11.4.5 Periodic Message Commands

All commands are listed in the Commands and Responses section at the end of this document.
A brief summary of them is provided here.
• 5x 63
• 7x 0C
• 7x 18
• 7x 1A
• 7x 1B
• 7x 1C

12. AVT-84x Field reFLASHing

All AVT-84x units can be reFLASHed in the field to permit updating the unit operating firmware.
12.1 AVT-84x reFLASHing - AVT Provided Application
AVT can provide stand alone applications for a host PC to reFLASH an AVT-841, 842, or 843 unit.
Host operating systems supported are: WIN98, WIN-NT, WIN-XP, WIN2000.
AVT-84x Multiple Interface
Timer interval
Periodic message group operation control (disabled, Type1, Type2)
Define a periodic message
Periodic message disable/enable
Periodic message interval
Disable all periodic messages
Disable all groups
Advanced Vehicle Technologies, Inc.
must use message $01 timer