Advantech AMAX-3245 User Manual page 16

Table of Contents

Advertisement

LINKO & LINK1 LED (Green)
LED Status
Last
Flash
Off
Run LED (Green)
LED Status
Off
Slow Flash
Single Flash
Last
Quick Flash
Err LED (Red)
LED Status
Off
Quick Flash
Single Flash
Double Flash
STS LED (Green)
LED Status
OFF
Flash
2.2.7.2
Running
LED
D7/10/13/16
D8/11/14/17
D9/12/15/18
AMAX-3245 User Manual
Connection Status
Yes
Yes
No
Salve Module Status
INITIALISATION
PRE-OPERATIONAL
SAFE-OPERATIONAL
OPERATIONAL
BOOTSTRAP
Error Description
Description
Salve module in
Correct
normal running
Wrong salve mod-
Wrong Configuration
ule configuration
Status switch
Wrong salve module
caused by mistakes
Data processing or
Watchdog timer
EtherCAT watchdog
overtime
timer overtime
Description
Power supply disconnection
The device in normal operation
Axis
Axis 0-4
Axis 0-4
Axis 0-4
Activation
Trigger Requirements
No
Port On / Connection
Yes
Port On / Connection
No
Port Off / Disconnection
Requirements
The device in initialization
The device in pre-operation
The device in safe-operation
The device in normal operation.
The device boots states
1.
The device is starting up and
doesn't begin initialization.
2.
The device is upgrading firm-
ware.
Reasons
1.
Wrong packet parame-
ters of EtherCAT cause
wrong salve module sta-
tus.
2.
Control chip in salve
module detects wrong
hardware configuration.
Synchronization errors cause
salve module turn from 0P to
Safe0P status.
Watchdog in Sync Manger over-
time
Name
Description
ORG
Home
LMT+
Limit+
LMT-
Limit-
10

Advertisement

Table of Contents
loading

Table of Contents