Network Monitoring Signal Tower with MP3 NH-FV Series Instruction Manual
-Microsoft Azure Procedures-

7.4. Cloud-to-Device Message fields

No.
Field name
1
alert
2
led
3
alert_do
4
clear
5
sound
6
repeat*
* Set a value of 255 for endless playback.
Caution: This will not run if an invalid value is specified.
Value
・Controls the signal light and buzzer.
・Set patterns in order: R (red) → Y (yellow) → G (green) → B (blue) → C (white)
→ Z (buzzer).
"6 digits"
・[RYGBC] - 0: light off, 1: light on, 2: flashing 1, 3: flashing 2, 9: no change
・[Z] - 0: No sound, 1: Buzzer pattern 1, 2: Buzzer pattern 2, 3: Buzzer pattern 3,
4: Buzzer pattern 4, 9: No change
・Controls the signal light.
"5 digits"
・Set patterns in order: R (red) → Y (yellow) → G (green) → B (blue) → C (white).
・[RYGBC] - 0: light off, 1: light on, 2: flashing 1, 3: flashing 2, 9: no change
・Controls digital output.
0,1,9
・0: OFF, 1: ON, 9: No operation
1
Turn off all signal lights and stop playing the current channel.
1 to 70
Play specified audio channel.
Play the audio channel defined by the [sound] instruction the number of times
0 to 255
specified here.
Description