Network Monitoring Signal Tower with MP3 NH-FV Series Instruction Manual
-Microsoft Azure Procedures-
7. Fields and descriptions
7.1. Device Twin fields
No.
Field name
1
led_red / led_red_c
2
led_yellow / led_yellow_c
3
led_green / led_green_c
4
led_blue / led_blue_c
5
led_white / led_white_c
6
buz_pattern / buz_pattern_c
7
sound_pattern / sound_pattern_c
8
digital_output / digital_output_c
Caution: This will not run if an invalid value is specified.
7.2. Direct Method fields
No.
Field name
1
alert
2
led
3
alert_do
4
clear
5
sound
6
repeat*
* Set a value of 255 for endless playback.
Caution: This will not run if an invalid value is specified.
0,1,2,3,9
0,1,2,3,4,9
1 to 70
0,1
Value
・Controls the signal light and buzzer.
・Set patterns in order: R (red) → Y (yellow) → G (green) → B (blue) → C (white)
→ Z (buzzer).
"6 digits"
・[RYGBC] - 0: light off, 1: light on, 2: flashing 1, 3: flashing 2, 9: no change
・[Z] - 0: No sound, 1: Buzzer pattern 1, 2: Buzzer pattern 2, 3: Buzzer pattern 3,
4: Buzzer pattern 4, 9: No change
・Controls the signal light.
"5 digits"
・Set patterns in order: R (red) → Y (yellow) → G (green) → B (blue) → C (white).
・[RYGBC] - 0: light off, 1: light on, 2: flashing 1, 3: flashing 2, 9: no change
・Controls digital output.
0,1,9
・0: OFF, 1: ON, 9: No operation
1
Turn off all signal lights and stop playing the current channel.
1 to 70
Play specified audio channel.
Play the audio channel defined by the [sound] instruction the number of times
0 to 255
specified here.
Value
0: Light off
1: Light on
2: Flashing 1
3: Flashing 2
9: Maintenance (no change)
0: Stop
1: Pattern 1
2: Pattern 2
3: Pattern 3
4: Pattern 4
9: Maintenance (no change)
Channel 1 to 70
0: OFF, 1: ON
Description
15
7. Fields and descriptions
Description
LED Unit (red)
LED Unit (yellow)
LED Unit (green)
LED Unit (blue)
LED Unit (white)
Buzzer control
Audio channel
Digital output