Troubleshooting Test C - Motor Start Error - Norcold DE105 Service Manual

Compressor refrigerators
Hide thumbs Also See for DE105:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting Test C - Motor Start Error

Remove refrigerator from
enclosure, but do not
disconnect DC power cord.
Turn thermostat to OFF for a
minimum of three (3) minutes
to allow internal system
pressures to equalize.
Turn thermostat to ON.
Do
three (3)
flashes
return?
YES
NOR000874A
www.norcold.com
NO
Repair complete.
Replace refrigerator.
11
Three (3) Flashes
Possible Cause:
The rotor is blocked or the differential
pressure in the refrigeration system is
too high ( >5 bar).
SERVICE MANUAL