Page 1
® AOYUE FEK-01 Fume Extractor Instruction Manual Thank you for purchasing the Aoyue FEK-01 Soldering Fume Extractor. Please read the manual before using the unit. Keep manual in accessible place for future reference.
This manual is designed to familiarize and instruct the technician with the proper operation and maintenance of the equipment. Please read carefully and observe the guidelines in order to maximize usage and minimize the risk of injury or accidents . TABLE OF CONTENTS Warnings …..……………………………………...
WARNING!!! REMOVE ALL PLASTIC COVERING FROM FEK-01 SYSTEM, ◆ PARTS AND COMPONENTS, CARBON FILTER AND HEPA FILTER. !RISK OF FIRE IF PLASTICS ARE NOT REMOVED! WARNING OVER EXTENDING ARM MAY UNBALANCE AND ◆ TOPPLE FEK-01 SYSTEM. When placing the HEPA filter into the unit make sure to place ◆...
SAFETY PRECAUTIONS CAUTION: Improper usage can cause serious injury to personnel and/ or damage to equipment and work area. For your own safety, please observe the following precautions. Check each component after opening the package to make ● sure everything is in good condition. If there are any sus- pected damage, do not use the item and report the issue to your vendor.
PRODUCT DESCRIPTION Portable Fume Extraction System with Integrated ◆ Filter Module includes HEPA Filter (High Efficiency Particulate Air filter) For Removing the Dust Particles and Enhanced Activated Carbon filtration system. With actual Carbon filter beads that trap odor and ◆ toxins .
PACKAGE INCLUSION 1 unit Station with Main filter and Carbon filter 2 pc. Extra activated carbon sub-filter pads 2 pc. Exhaust arm kit Filter hood with LED lamp and activated 2 pc. carbon sub-filter pads 1 pc. Air inlet cover for single arm operation 4 pc.
BOX CONTENTS 1 pc. Main external box (BOX A) 1 pc. FEK Station box (BOX B) 2 pc. Filter hood box (BOX C) 1 pc. Parts box (BOX D) BOX A Main external box contents Arm x2 FEK Station box (Box B) x1 Filter hood box (Box C) x2 Parts box (Box D) x1 BOX B FEK station box contents...
SPECIFICATION Voltage Input : available in 110V / 220V Dimensions: 320(w) x450 (h) x 260 (d) mm Weight: 8.5Kg Power Consumption: 80-200W Filter: HEPA Filter / Carbon Filter Filter hood Exhaust Air duct Power Switch DISPLAY Controls Connector CARBON FILTER...
CONTROL PANEL GUIIDE SPECIFICATION 1. Selected power display 2. ON/OFF button (long press to activate, long press to deactivate). 3. Increase button 4. Decrease button...
OPERATING GUIDELINES Assembly: A. Attach Wheels Attach wheels B. Remove Plastic coverings of the carbon filter and HEPA filter. Pull out FEK-CF carbon filter and remove plastic covering before usage. Unlock top cover and pull out the FEK-MF HEPA filter. Remove plastic covering from HEPA filter.
Page 11
OPERATING GUIDELINES C. Attach filter hood with securing screw. Remove tape to reveal three 3x6mm Filter Hood screw attached to the arms (an arrow points to the screws) There is around 3mm space between the arm and the screw head to be able to slide into the provided u-slot Push arm fully into the hood then tighten the screws.
Page 12
OPERATING GUIDELINES D. Attach Arm for single or double fume extraction operation. Single Fume Dual Fume Extraction Extraction operation operation Attach air inlet cover for single fume extraction operation Simply slide in the arm...
Page 13
OPERATING GUIDELINES E. Insert Battery for filter hood Slide open battery cover Battery Switch to insert battery cover F. Fully assembled Unlock to access HEPA filter Unlock to access HEPA filter Pull out carbon filter using the two white tabs.
Page 14
OPERATING GUIDELINES REMINDERS: 1. Make sure the equipment is placed on a flat stable surface and do not over extend arm as there is risk of unit toppling. 2. Ensure all function switches are in the OFF position. 3. Ensure all terminal connections are properly secured. Please refer to the CONTROL PANEL IMPORTANT: GUIDE page for button switches.
Page 15
OPERATING GUIDELINES B. HEPA FILTER and CARBON FILTER REPLACEMENT HEAPA and Carbon filter may need replacement after 3 months depending on usage, It is recommended to replace car- bon filter and heap filter at the same time for best perfor- mance.
Page 16
Repeat above steps to switch to correct frequency. Warning: If wrong frequency is selected the system’s air suction controls will behave erratically or be uncontrollable. Select to correct line frequency to enable normal usage. AOYUE INTERNATIONAL LIMITED Jishui Industrial Zone, Nantou, Zhongshan City, Guangdong Province, P.R.China http://www.aoyue3d.com...
Need help?
Do you have a question about the FEK-01 and is the answer not in the manual?
Questions and answers