Continuum Maestro Opus User Manual

Pedicure chair
Hide thumbs Also See for Maestro Opus:

Advertisement

Quick Links

USER MANUAL
Maestro Opus Pedicure Chair
1-400-0088 • Rev A • 2/5/2020
*shown with optional accessories and/or finishes
© Continuum 2020, All Rights Reserved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Maestro Opus and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Continuum Maestro Opus

  • Page 1 USER MANUAL Maestro Opus Pedicure Chair 1-400-0088 • Rev A • 2/5/2020 *shown with optional accessories and/or finishes © Continuum 2020, All Rights Reserved...
  • Page 2 Continuum® ment. This document may contain technical inaccura- cies or errors. Continuum® makes no expressed or im- All rights reserved. This document or plied warranties of any kind concerning the information...
  • Page 3: Table Of Contents

    Relaxor heat and massage system. The Maestro Opus is designed for licensed therapists and technicians and is intended to be used in a professional spa, salon, or similar commercial environment. While no special training is needed to operate the product, for safety reasons it is important that the instructions contained in this manual are reviewed in detail before the first use.
  • Page 4: Section 1: Safety Information

    Familiarize yourself with the following or fatal injury. Safety & Warning symbols. They are designed prevent damage injury to you, your clients, and your new Continuum product. Indicates a potentially hazardous situation which could result in serious injury. IMPORTANT: important safety...
  • Page 5 SECTION 1: SAFETY INFORMATION • DO NOT reach for any electrical object that has fallen into the water. Unplug immediately. • DO NOT drop or insert anything into jet opening. • DO NOT operate without the complete jet assembly installed or without water filled 1 inch above jets. •...
  • Page 6: Section 2: Product Overview

    SECTION 2 : PRODUCT OVERVIEW Client Controls Electronic Footrest Chair Swivel Release USB Port Jet Button Sprayer/Fill Drain Pump Button Drain (Optional) Release Drain Pump Button Cupholder Pipeless Jet Light Button Technician Water Fill Controls Valve Vent *Chair shown with optional finishes...
  • Page 7: Product Specifications

    SECTION 2 : PRODUCT OVERVIEW Product Specifications Length 61.25” (156 cm) 36” (92 cm) Width 44.75” (113 cm), with side trays Overall Height 52” (132 cm) Seat Height 23.5” (60 cm) Weight Capacity 300 lbs Basin Capacity 5.7 gallons *Measurements may vary due to natural material variations. Included Features Feature Standard...
  • Page 8: Section 3: Operating Instructions

    Leveling, or balancing, your chair is very important during initi al setup and routi ne maintenance. Your Maestro Opus is equipped with six (6) leveling feet. NOTE: Leveling feet have been adjusted prior to shipment - in most cases no further adjustment should be necessary.
  • Page 9: Gravity Drain & Drain Pump

    SECTION 3: OPERATING INSTRUCTIONS Draining the Tub Gently turn drain handle located on right side of base. This acti vates “Pop-Up” located on bott om of basin allowing water to drain. Wait for the air bubbles to exit. Press chrome butt on marked “DRAIN” to acti vate pump. When basin is fully empti ed, press butt on again to turn the pump off .
  • Page 10: Technician Controls

    SECTION 3: OPERATING INSTRUCTIONS Technician Controls See below for technician controls functionality. Always use extreme caution when making any position adjustments to the chair. Ensure all body parts and objects are clear from all moving parts. Raise/lower Raise/lower Slide seat right footrest left footrest forward/backward...
  • Page 11: Client Controls

    SECTION 3: OPERATING INSTRUCTIONS Embedded Client Control The following photo shows the functionality of the Maestro Opus embedded control. Slide seat forward/backward Seat base tilt increase/decrease Seat back tilt increase/decrease Relaxor Heat & Massage Hand Control RISK OF ELECTRIC SHOCK Keep hand control and all electrical components away from water.
  • Page 12: Section 4: Care & Maintenance

    SECTION 4: CARE & MAINTENANCE Cleaning & Ongoing Maintenance The following procedures are important guidelines that will help in keep your Maestro Opus clean and trouble free for years. It is extremely important to clean and disinfect every pedicure chair after each pedicure and after the last pedicure of the day. (See next page for instructions.) YOU ARE REQUIRED TO CHECK WITH YOUR STATE BOARD FOR MANDATORY CLEANING AND DISINFECTING REQUIREMENTS AND PROCEDURES.
  • Page 13: Tub Cleaning Guide

    If the wet end is not positioned correctly, damage to the jet may occur due to misalignment. This will NOT be covered by any Continuum warranty. Never turn the jet on without adequate water in the basin. There must be at least one (1) inch of water above the motor housing.
  • Page 14: Troubleshooting

    In the event your specific situation is not covered in this guide, please contact Continuum so our technical support department can assist you. Beyond the troubleshooting guide below, do not attempt to repair the issue yourself.
  • Page 15: Warranty Information

    Canada and Mexico All warranties are limited to repair or replacement, at Continuum’s discretion, unless otherwise stated. This limited warranty applies only to pedicure chairs installed in any one of the fifty (50) States of the United States, the District of Columbia, or provinces...