Mannesmann Rexroth TVD 1.3 Series Applications Manual page 20

Power supply module for direct connection to 3 x ac 380...480v mains supply
Table of Contents

Advertisement

Mains connection via a
transformer
PE
L1
L2
L3
1) min. lead cross section ..........................................4 mm
2) min. lead cross section: ........................................2,5 mm
3) ≥ 10 mm
Lead cross section per EN 60204 - installation type B1 - correcting factors not taken into account
• DOK-POWER*-TVD*1.3****-ANW1-EN-E1,44 • 02.97
3. Electrical Connections
If the modular drives are to be operated in residential or light
industrial areas, then it may be necessary to mount an rf interference
filter to maintain the limit values for the emission of interference (rf
interference suppression).
Each drive module must be connected to the PE-rail of the TVD with a separate
ground lead.
The leakage current via the protective conductor is greater than 3.5
mA AC. A permanent connection is thus required for the TVD.
A transformer is needed if the mains voltage is less than 3 x 380V or greater
than 3 x 480V.
The mains inductance (leakage inductance) from transformers can vary
significantly depending on power and type of construction. Mains connection
components are therefore still needed even if transformers are used (see
section 3.3.).
Required transformer power:
S
=
Tr
P
=
DC
U
=
N
stranded,
max.
2 m lang
3)
PE
NAM 1.3- . .
2L+
1L+
N
P
U1
U2
V1
V2
W1
W2
IN 175/155
min. lead cross section: .........................................16 mm with TVD 1.3-15
min. lead cross section ...........................................6 mm
2
Fig. 3.6:
Mains connection TVD 1.3 via a transformer
× 3×U
P
DC
N
=
S
TR
25,5
transformer power in VA
DC bus continuous power in W
transformer output voltage in V
3)
X12
1)
X7/2L+
X7/1L+
2)
X8/N
X8/P
2)
X7/1U1
X7/1V1
X7/1W1
16-pin bus cable
(NAM blower power source)
TVD 1.3
L+
L-
TVD/NAM12Trafo
2
with TVD 1.3-08
2
2
with TVD 1.3-08
2
with TVD 1.3-15
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tvd 1.3-15-3Tvd 1.3-08-3

Table of Contents