Mannesmann Rexroth TVD 1.3 Series Applications Manual page 18

Power supply module for direct connection to 3 x ac 380...480v mains supply
Table of Contents

Advertisement

TVD 1.3 with separate
components
GLD . .
N
CZ 1.2-01-7
KD . .
U1
L1
V1
L2
W1
L3
1) min. lead cross section: ..........................................4 mm
min. lead cross section: .........................................16 mm with TVD 1.3-15
2) min. lead cross section: ........................................2.5 mm wth TVD 1.3-08
min. lead cross section: ...........................................6 mm with TVD 1.3-15
3) ≥ 10 mm
Lead cross sections per EN 60204 - installation type B1 - correcting factors not taken into account
• DOK-POWER*-TVD*1.3****-ANW1-EN-E1,44 • 02.97
3. Electrical Connections
If modular installation is not possible due to space restrictions, then the supply
module can also be connected to the mains via separate components.
Required components:
Supply module
TVD 1.3-08-3
TVD 1.3-15-3
3)
PE
1
1)
2
stranded, max.
2 m long
2)
P
3)
PE
3)
PE
U2
2)
V2
W2
stranded,
max.
15 m long
2
Fig. 3.4:
Connecting a TVD 1.3 to the mains with individual components
Commutation
Buffer
choke
capacitor smoothing choke
KD 26
CZ 1.2-01-7
KD 23
CZ 1.2-01-7
X12
X7/2L+
X7/1L+
TVD 1.3
X8/N
X8/P
3)
X12
X7/1U1
X7/1V1
X7/1W1
DC bus
GLD 16
GLD 17
L+
L-
TVD/CZ1201
2
with TVD 1.3-08
2
2
2
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tvd 1.3-15-3Tvd 1.3-08-3

Table of Contents