Trouble Shooting
Error Type
Error Mode
The Cycle does
None
not start.
No Washing
None
Checking Method
1. Check the connections for the Door Sensing Switch
: Check the blue wire and the switch connected to the blue
wire.
➢ Normal (Power Key On): 9.5 to 12.5V (when the
door is open)
➢ Normal (Power Key Off): 5.5 to 7.0V (when the door
is open)
➢ Normal : <2V (when the door is closed)
2. Check the operation of the Door Sensing Switch.
(Remove the connector before measuring.)
: Check the blue wire and the switch connected to the blue
wire.
➢ Normal: OPEN (when the door is open)
➢ Normal: SHORT (when the door is closed)
1. Check whether the nozzle injects water normally.
2. Check the operation of the Heater.
Corrective actions
- Reconnect the Door Sensing Switch connectors
- Faulty: Replace the Door Sensing Switch.
- Normal: Replace the Main PBA assy.
- See "The nozzle does not inject water".
- See "Heater Error".